dc.description.abstractResumen .- En el presente proyecto se realiza el análisis de una edificación esencial de seis pisos, en la cual primero se recurre a un Análisis Lineal para obtener el diseño estructural del edificio; y consecutivamente se verifica el desempeño de la estructura con la ayuda de un Análisis Estático No Lineal o NSP. Dentro del análisis lineal, el modelo matemático tridimensional de la estructura se desarrolla con el software SAP2000 y con los resultados del modelo se diseñan vigas y columnas que conforman la edificación; el diseño toma en cuenta las recomendaciones del código ACI 318-08 y del cuerpo normativo NEC. El análisis NSP se basa en la metodología de zonas plásticas y se aplica a un pórtico central, en cada dirección principal de la estructura. Este análisis se realiza con el software SAP2000, el cual emplea los criterios de los códigos FEMA 356 y ATC 40, para obtener el desempeño estructural. Dentro del NSP, se realizan 20 modelos con distintas variaciones de zonas plásticas en cada pórtico que se analiza. Finalmente se verifica el desempeño de la estructura y el probable nivel de daño que pueda presentar la edificación, en función de los puntos de desempeño de los modelos realizados. Abstract .- This project presents an analysis of the six-story building, in which first a Linear Analysis is used for the structural design of the construction; and sequentially performing the structure is verified with the aid of a Nonlinear Static Analysis or NSP. Within the Linear Analysis, three-dimensional mathematical model of the structure develops with the software SAP2000 and with the model results beams and columns that make up the building are designed; The design takes into account the recommendations of ACI 318-08 code and the regulatory body NEC. NSP analysis is based on the methodology of plastic zones and is applied to a central portal in each principal direction of the structure. This analysis is performed with the software SAP2000, which uses the criteria FEMA 356 and ATC 40 codes for structural performance. Within the NSP, 20 models with different variations of plastic zones in each portico analyzes are performed. Finally the performance of the structure and the likely level of damage that may occur in the building, depending on the points of performance of all models made is verified.es_ES
dc.description.sponsorshipCeli Sánchez, Carlos Andrés, directores_ES
dc.language.isospaes_ES
dc.publisherQuito : EPN, 2015.es_ES
dc.rightsopenAccess-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectEstructuras (Construcción)es_ES
dc.subjectTécnica Pushoveres_ES
dc.titleDiseño estructural de una edificación de seis pisos, mediante un análisis lineal controlado por derivas inelásticas y una comprobación con un análisis estático no lineal, aplicando la técnica del pushoveres_ES