Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/10787
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorLópez Carrión, Alexis Paúl-
dc.date.accessioned2015-06-19T14:26:48Z-
dc.date.available2015-06-19T14:26:48Z-
dc.date.issued2015-06-18-
dc.identifier.otherT-IM/1748/CD 6319-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/10787-
dc.description150 hojas : ilustraciones, 29 x 21 cm + CD-ROM 6319es_ES
dc.description.abstractResumen .- La naturaleza del nuevo Sistema de Alivio es de seguridad operacional, pues protege al personal de la planta, instalación y medio ambiente de sobre presiones inadvertidas que superen la resistencia mecánica de los equipos del proceso involucrados. Debido a que las válvulas reducen la presión al momento del disparo, el flujo de alivio que emerge de los equipos será dirigido al respectivo cabezal, considerando que solo se presentará un evento a la vez. Para hallar los diámetros del cabezal y las líneas secundarias se utilizó el Simulador Inplant Versión 4.0. La descarga de líquido retenido en el K.O.D, se efectuará mediante un sistema de control de interruptores de nivel. La Especificación de Materiales y el cálculo del espesor de tubería se fundamentaron en Normas Internacionales y criterios de buenas prácticas de Ingeniería tomándose como referencia principal la Norma Técnica PIP y la Norma ASME B31.3. En la última parte del proyecto se utilizó el programa Cadworx 2010 que generó los planos isométricos y posteriormente el listado de materiales, y con la ayuda de este listado se realizó un presupuesto referencial cuyo precio asciende a los $ 68.678,80 dólares, que constituye solo el costo del material antes de ser instalado. Abstract.- The nature of the new system of Relief is operational safety, by protecting the personnel at the plant, installation, and the environment from unnoticed pressure exceeding the mechanical strength of the equipment involved in the process. Since the valves reduce pressure at the time of the shooting, the flow of relief that emerges in the equipment will be directed to the respective head, considering that only an event at a time will be presented. Inplant Simulator Version 4.0 was used to find the diameter of the head and branch lines. The discharge of liquid retained in the K.O.D shall be made by means of a control system of level switches. The piping class and the calculation of the thickness of pipe was based on international standards and the criteria of good engineering practices, having PIP as main technical reference and the standard ASME B31.3. On the last part of the project, the software Cadworx 2010 generated isometric plans, and later the list of materials and with the help of this list a referential budget took place, whose price amounts to $68.678, 80 dollars that only constitutes the costs of the materials before the installation.es_ES
dc.description.sponsorshipRojas Morillo, Eduardo José, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2015.es_ES
dc.rightsopenAccess-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectMecánica de fluidoses_ES
dc.subjectEvaluación de proyectoses_ES
dc.titleEvaluación de escenarios y determinación de contingencia crítica para el diseño de un sistema de alivio de una planta destiladora de crudo para la empresa Downstreamses_ES
dc.typebachelorThesises_ES
Aparece en las colecciones:Tesis Mecánica (IM)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CD-6319.pdf7,53 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.