Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/11301
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorAnasi Gualotuña, Oscar Danilo-
dc.contributor.authorArévalo Chafuel, Diego Armando-
dc.date.accessioned2015-08-04T20:41:42Z-
dc.date.available2015-08-04T20:41:42Z-
dc.date.issued2015-08-03-
dc.identifier.citationAnasi Gualotuña, O. D., & Arévalo Chafuel, D. A. (2015). Análisis comparativo de muros de cortante de hormigón armado con diferente relación de aspecto a través de ensayos de carga lateral en el plano. 134 hojas. Quito.es_ES
dc.identifier.issnT-MVE/0353/CD 6430-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/11301-
dc.descriptionEn esta tesis se describe el estudio teórico y la contrastación con ensayos de laboratorio de tres muros de cortante analizando la respuesta de carga – desplazamiento. Se pretende validar los modelos matemáticos con los ensayos experimentales de laboratorio. Los tres muros de cortante se identifican como M1, M2, y M3. El muro M1, con relación de aspecto, menor a dos, se diseña para que presente un agotamiento a corte. El muro M2, con relación de aspecto mayor a dos, se diseña para que se presente un agotamiento a flexión. El muro M3, con relación de aspecto mayor a dos, se diseña esperando un agotamiento a corte. Se determina la demanda en función de la capacidad teórica de cada muro. Se realizan los ensayos y se obtienen los parámetros de resistencia de la curva carga-desplazamiento. Se describe el agotamiento de los muros y se analizan los resultados del ensayo. Se comparan los resultados de la curva carga-desplazamiento obtenidos mediante el SAP2000, el ATC-40 y el modelo experimental.es_ES
dc.description.abstractThis thesis discusses a theoretical study and a comparison with lateral force-displacement tests of three shear walls. The three shear walls are called as M1, M2, and M3. M1 shear wall has an aspect ratio less than two, and it is designed to show a shear failure. M2 shear wall has an aspect ratio greater than two, and it is designed to show a flexural failure. M3 shear wall has an aspect ratio greater than two, and it is designed to show shear failure. Shear wall demand is determined based on theoretical capacity of every wall. After testing, it is obtained resistance parameters from forced-displacement curve. It is described failure of shear walls, and results are analyzed. Finally, results using SAP 2000, el ATC-40, and the experimental model are compared.es_ES
dc.description.sponsorshipPlacencia Andrade, Patricio Honorato, Director.es_ES
dc.language.isospaes_ES
dc.publisherQuito, 2015.es_ES
dc.rightsopenAccess-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectMuros de cortantees_ES
dc.subjectIngeniería sismorresistentees_ES
dc.subjectDiseño estructurales_ES
dc.subjectHormigón armadoes_ES
dc.titleAnálisis comparativo de muros de cortante de hormigón armado con diferente relación de aspecto a través de ensayos de carga lateral en el planoes_ES
dc.typemasterThesises_ES
Aparece en las colecciones:Tesis Maestría en Estructuras (FICA)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CD-6430.pdf6,92 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.