Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/11365
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorLoja Gutama, Tania Carolina-
dc.date.accessioned2015-08-12T01:43:37Z-
dc.date.available2015-08-12T01:43:37Z-
dc.date.issued2015-08-07-
dc.identifier.citationLoja Gutama, T. C. (2015) Diseño a escala piloto de un sistema de eliminación de fenoles en aguas residuales de una empresa textil empleando dióxido de cloro. 136 hojas. Quito.es_ES
dc.identifier.otherT-IQ/0967/CD 6450-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/11365-
dc.descriptionEl presente trabajo tuvo como objetivo el diseño a escala piloto de un sistema de eliminación de fenoles en aguas residuales provenientes de la industria textil empleando dióxido de cloro. Para el desarrollo del proyecto se trabajó experimentalmente en el laboratorio Acelerador de Electrones de la EPN, se trabajó con muestras compuestas recolectadas mediante los muestreos previos del agua residual en la empresa textil, se adecuó el agua residual a distintos pH para determinar el rango al que mejor actuaba el dióxido de cloro estabilizado en solución acuosa y así determinar las mejores condiciones de trabajo para la remoción de fenoles. Se planteó un diseño experimental factorial 3 x 3 cuyos niveles de pH fueron 5, 7 y 9 del agua residual y para la concentración de dióxido de cloro 2,5%; 6,5% y 10% estabilizado en solución acuosa, se trabajó con dos repeticiones y se tuvo como variable de salida la concentración final de fenoles. Mediante un análisis estadístico realizado con datos obtenidos experimentalmente en el laboratorio se determinó que durante el tratamiento del agua residual con dióxido de cloro por un tiempo de contacto de 30 minutos se obtuvo una mejor remoción de fenol cuando el agua se encontraba a pH 9 y el dióxido de cloro en una concentración del 10%. Bajo las condiciones anteriores se obtuvo un porcentaje de remoción de fenol del 90,49%. Se realizó el estudio de la cinética de reacción entre el fenol presente en el agua residual a pH 9 y dióxido de cloro en solución acuosa estabilizado al 10%, mediante el método integral para determinar orden de las reacciones se demostró que es de segundo orden con una constante de velocidad de reacción de 0,541 L x mg-1 x min-1. Se diseñó a escala piloto el sistema de eliminación de fenoles presentes en el agua residual capaz de tratar 8 000 L/día y se realizó una comparación de costos al emplear peróxido de hidrógeno cuya concentración es del 10%. El diseño del sistema a escala piloto para la eliminación de fenoles presentes en 1 m3 de agua residual con tiempo de contacto 30 minutos con dióxido de cloro dio una concentración final de fenol de 0,051 mg/L, en consecuencia cumple con la Norma Técnica de Calidad Ambiental para la descarga de efluentes líquidos al sistema de alcantarillado que permite un máximo de 0,2 mg/L de fenol que se establece en el TULSMA.es_ES
dc.description.abstractThis study had an objective to design a pilot scale of a system of elimination of phenols in wastewater from the textile industry using chlorine dioxide level. To develop the project, it worked experimentally on electron accelerator laboratory of the EPN, it worked with composite samples collected by previous samples of the wastewater in the textile company, the wastewater at different pH was adapted to determine the range that best range which acted better the chlorine dioxide in aqueous solution, thus to determine the best working conditions for the removal of phenols. A factorial experimental design was presented 3 x 3 whose pH levels were 5, 7 and 9 of the wastewater and to the chlorine dioxide concentration 2.5%; 6.5% and 10% stabilized in aqueous solution. It worked with two repetitions and had as output variable the final concentration of phenols. Trough statistical analysis made with data got experimentally, it was determined in the laboratory during the treatment of wastewater with chlorine dioxide by a contact time of 30 minutes. It got a better removal of phenol when the water was at pH 9 and chlorine dioxide at a concentration of 10%. Under those conditions, a percentage of phenol removal of 90.49% was obtained. The study of the kinetics of reaction between the phenol present in the waste water to pH 9 and chlorine dioxide stabilized in aqueous solution 10% was performed using the integral method for determining order of reactions was shown that is second order with a constant reaction rate of 0.541 L x mg-1 x min-1. It was designed to scale pilot the removal system phenols present in the wastewater able to treat 8000 L / day it was made a cost comparison was performed by using hydrogen peroxide whose concentration is 10%. The pilot system design for removing of phenols present in 1 m3 of wastewater scale with a contact time of 30 minutes with chlorine dioxide gave a final phenol concentration of 0.051 mg / L, therefore it meets the Standard Technical Environmental Quality for discharging of wastewater into the sewage system that allows a maximum of 0.2 mg / L of phenol as set forth in the TULSMA.es_ES
dc.description.sponsorshipAldás Lara, Mario Aníbal, Director.es_ES
dc.language.isospaes_ES
dc.publisherQuito, 2015.es_ES
dc.rightsopenAccess-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectFenoleses_ES
dc.subjectOxidaciónes_ES
dc.subjectAguas residualeses_ES
dc.titleDiseño a escala piloto de un sistema de eliminación de fenoles en aguas residuales de una empresa textil empleando dióxido de cloroes_ES
dc.typebachelorThesises_ES
Aparece en las colecciones:Tesis Ing. Química (IQUIM)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CD-6450.pdf2,12 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.