dc.contributor.author | Espín Zurita, María Belén | - |
dc.date.accessioned | 2015-11-24T20:20:06Z | - |
dc.date.available | 2015-11-24T20:20:06Z | - |
dc.date.issued | 2015-11-23 | - |
dc.identifier.citation | Espín Zurita, M. B. (2015). Desarrollo de un modelo digital para la optimización del proceso de irradiación de guantes quirúrgicos en la fuente de cobalto-60 de la EPN a través del software MCNP5. 236 hojas. Quito : EPN. | es_ES |
dc.identifier.other | T-IQ/0971/CD 6608 | - |
dc.identifier.uri | http://bibdigital.epn.edu.ec/handle/15000/11990 | - |
dc.description | Se desarrolló un modelo digital en el MCNP5 que permite determinar las dosis máxima (dmáx) y mínima (dmín) absorbidas, su distribución y la razón de uniformidad de dosis, DUR en 4 cajas máster de guantes de látex ubicadas a 20 cm alrededor de la fuente de cobalto-60 de la EPN. Los datos obtenidos en la simulación fueron comparados con valores de dosis experimentales medidos mediante el sistema dosimétrico red perspex que fue calibrado con referencia al dosímetro cérico-ceroso, cuya incertidumbre expandida fue de 8,6 % para un k=2. Los guantes de látex estaban contenidos en 10 cajas pequeñas de 20x6x11 cm, y éstas dentro de cajas máster de cartón de 31,5x21x23,4 cm. Se dispuso 45 dosímetros red perspex dentro de cada caja máster y éstas se ubicaron de la misma manera que en el modelo, para su irradiación. Los valores de dosis obtenidos fueron: dmáx 33,0 kGy, dmín 14,8 kGy y DUR 2,2. Se desarrollaron ajustes en el modelo digital hasta que el error relativo entre los valores simulados y los experimentales sea menor a 25 %. El modelo final presentó un error relativo de 7,2 %, por lo tanto fue validado, con este modelo se realizó el rediseño de la fuente de cobalto-60 para una recarga de 64 000Ci y 100 000 Ci. Se determinó que para alcanzar valores de DUR de 1,5 con la recarga de 64 000 Ci se debe recargar al menos 6 lápices con 10 500 Ci, y con la recarga de 100 000 Ci se debe ubicar 20 lápices FS6008 de 5 000 Ci en pares uno sobre otro. | es_ES |
dc.description.abstract | A digital model that determines the maximum and minimum absorbed dose, its distribution and the DUR in 4 master boxes of rubber globes was developed. The data obtained through simulation where compared to experimental data that was obtained using red perspex dosimeter, which was calibrated using the ceric-cerous sulfate dosimeter at the EPN irradiator, which expanded uncertainty was 8,6 % with a k=2. 45 red Perspex were located at each master box whose dimensions were 31,5 x 21 x 23,4 cm. Ten individual small boxes of 20 x 6 x 11 cm were into the master boxes. The master boxes were located at 20 cm from the center of the source. The dose values obtained were: dmáx 33,0 kGy, dmín 14,8 kGy y DUR 2,2. In order to validate the digital model, the model was adjusted to achieve relative error lower than 25% while comparing data obtained by experimentation to data obtained through simulation. The final model relative error achieved was 7,2%. This validated model was used to design the recharge of cobalt-60 source located at EPN with 64 000 Ci and 100 000 Ci. It was determined that in order to achieve a DUR of 1,5 at least 6 pen of 10 500 Ci has to be changed to 64 000Ci, and that 20 FS6008 pens of 5 000Ci should be located in pairs, one over the other, in a radius of 6 cm to 100 000 Ci recharge. | es_ES |
dc.description.sponsorship | Luna Aguilera, Gloria Maribel, director | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Quito, 2015. | es_ES |
dc.rights | openAccess | - |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | - |
dc.subject | Estadística | es_ES |
dc.subject | Probabilidad | es_ES |
dc.subject | Modelos matemáticos | es_ES |
dc.title | Desarrollo de un modelo digital para la optimización del proceso de irradiación de guantes quirúrgicos en la fuente de cobalto-60 de la EPN a través del software MCNP5 | es_ES |
dc.type | bachelorThesis | es_ES |
Aparece en las colecciones: | Tesis Ing. Química (IQUIM) |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
CD-6608.pdf | 5,94 MB | Adobe PDF | Visualizar/Abrir |