Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/13630
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorJiménez Analuiza, David Javier-
dc.date.accessioned2016-01-22T22:21:35Z-
dc.date.available2016-01-22T22:21:35Z-
dc.date.issued2015-12-01-
dc.identifier.citationJiménez Analuiza, D. J. (2016). Ubicación Óptima de Unidades de Medición Sincrofasoriales Pmu’s para Mejorar la Observabilidad de un Sistema Eléctrico de Potencia. 146 hojas. Quito : EPN.es_ES
dc.identifier.otherT-IE/4203/CD 6726-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/13630-
dc.descriptionEn este proyecto de titulación se analizará la ubicación óptima de las unidades de medición sincrofasoriales (PMU’s) en los sistemas eléctricos de potencia considerando la existencia de medidas convencionales o solamente el uso de PMU´s con el objetivo de hacerlos completamente observables. Las PMU’s tienen aplicaciones en la estimación de estado en condiciones normales de operación, y detección de fallas, medición y control en condiciones anormales, en el trabajo se analizará específicamente para condiciones normales de operación. Los sistemas IEEE 14, 30, 57, 118 y el SNI (Sistema Nacional Interconectado Ecuatoriano) serán probados en la realización de este trabajo. Para plantear el problema de la ubicación óptima se procedió a analizar los datos disponibles de los sistemas, como son sus topologías, mediciones convencionales, así como el número y ubicación de las barras de inyección cero. Dos métodos de optimización serán utilizados para la solución del problema, en primera instancia la función propia del programador matemático MatLab llamada bintprog, y en segunda el algoritmo heurístico de optimización binaria por enjambre de partículas (BPSO) desarrollado por los autores.es_ES
dc.description.abstractIn this project the optimal location of sincrofasoriales measurement units (PMU's) will be analyzed in electric power systems considering the existence of conventional measures or the use of PMU's only in order to make them fully observable. The PMU's have applications in the estimation of state under normal operation and fault detection, measurement and control in abnormal conditions, work was specifically analyzed for normal operating conditions. The IEEE 14, 118 and the SNI (Ecuadorian National Interconnected System) systems will be tested in carrying out this work. To pose the problem of the optimal location we proceeded to analyze data systems available, as are their topologies, conventional measurements as well as the number and location of bus injection zero. Two optimization methods will be used for solving the problem in the first instance the proper function of MatLab programmer mathematician called bintprog, and second heuristic algorithm binary particle swarm optimization (BPSO) developed by the authors.es_ES
dc.description.sponsorshipVargas Contreras, Walter Alberto, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2016.es_ES
dc.rightsopenAccess-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectSistemas eléctricos de potenciaes_ES
dc.subjectMedición sincrofasoriales_ES
dc.titleUbicación Óptima de Unidades de Medición Sincrofasoriales Pmu’s para Mejorar la Observabilidad de un Sistema Eléctrico de Potenciaes_ES
dc.typebachelorThesises_ES
Aparece en las colecciones:Tesis Ingeniería Eléctrica (IE)