Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/15067
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorAlbarrasín Veintimilla, Ángel David-
dc.date.accessioned2016-03-18T17:38:23Z-
dc.date.available2016-03-18T17:38:23Z-
dc.date.issued2016-03-10-
dc.identifier.citationAlbarrasín Veintimilla, A. D. (2016). Protección a los aerogeneradores contra descargas atmosféricas en parques eólicos, aplicación parque eólico Villonaco. 200 hojas. Quito : EPN.es_ES
dc.identifier.otherT-IE/4241/CD 6879-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/15067-
dc.descriptionEl presente proyecto de titulación tiene como objetivo realizar una metodología técnica para definir la protección externa en los aerogeneradores contra la afectación que presentan las descargas atmosféricas en parques eólicos. En este contexto se presenta un estudio detallado sobre la evaluación de la frecuencia de impactos directos para definir el entorno electromagnético del rayo sobre la estructura del aerogenerador en base a un Nivel de Protección adecuado (LPL) y que por medio del modelo electrogeométrico “esferas rodantes” se determina las Zonas de Protección contra el Rayo (LPZ). Tomando como referencia los criterios de la Norma IEC 61400-24 se realiza la metodología técnica para la protección del aerogenerador contra la influencia de interferencias conducidas en las fronteras de las zonas de protección contra rayos a través de los sistemas de captación, conducción del rayo y el Sistema de Puesta a Tierra (SPAT). Este trabajo finaliza con la presentación de un caso de estudio como aplicación el Parque Eólico Villonaco, en el cuál se ha implementado la metodología expuesta para la protección contra descargas atmosféricas.es_ES
dc.description.abstractThis degree project aims to perform a technical methodology to define the external protection wind turbines against the affectation that present the lightning at wind farms. In this context is presented a detailed study on the evaluation of the frequency of direct strokes to define the electromagnetic environment of the lightning on the structure of the wind turbine based on a Level of Protection appropriated (LPL) and through the electromagnetic model "rolling spheres" is determined the Lightning Protection Zones (LPZ). With reference to the criteria of the standard IEC 61400-24, the technical methodology is developed for the protection of the wind turbine from the influence of interference conducted at the borders of the zones of lightning protection through capture systems, conduction of lightning and Earthing System (SPAT). This work ends with the presentation of a case study as an application the Villonaco Wind Park, which has been implemented the methodology exposed for protection against lightning.es_ES
dc.description.sponsorshipRuales Corrales, Luis Edmundo, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2016.es_ES
dc.rightsopenAccess-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectAlto voltajees_ES
dc.subjectEnergías alternativases_ES
dc.subjectNivel de protección adecuado (LPL)es_ES
dc.titleProtección a los aerogeneradores contra descargas atmosféricas en parques eólicos, aplicación parque eólico Villonacoes_ES
dc.typebachelorThesises_ES
Aparece en las colecciones:Tesis Ingeniería Eléctrica (IE)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CD-6879.pdf7,54 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.