Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/15172
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorAlvaro Gualoto, Alba Eunice-
dc.date.accessioned2016-04-13T20:22:48Z-
dc.date.available2016-04-13T20:22:48Z-
dc.date.issued2016-04-06-
dc.identifier.citationAlvaro Gualoto, A. E. (2016). Rehabilitación y automatización del caldero Columbia CT-6 de la planta piloto de Ingeniería Química y Agroindustrial. 161 hojas. Quito : EPN.es_ES
dc.identifier.otherT-IE/4262/CD 6951-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/15172-
dc.descriptionEn el presente trabajo se detalla la rehabilitación y automatización del Caldero Columbia CT-6 ubicado en la planta piloto de la Facultad de Ingeniería Química y Agroindustria de la Escuela Politécnica Nacional. El caldero Columbia CT-6 dejó de funcionar por 4 años, por lo cual se procede a realizar un estudio de su estado actual y posteriormente realizar la automatización utilizando los elementos y partes del caldero que se encuentran en buen estado, por ejemplo presostatos, electrodos de nivel y manometro considerando primordial la seguridad de los usuarios. Adicionalmente se adquirió un RTD SITRANS-TS500 para la visualización y monitoreo de la temperatura del vapor de agua en tiempo real y como unidad central de control un PLC S7-1200 de la marca SIEMENS. La interfaz para controlar el caldero desde el puesto de trabajo del operario es realizada en InTouch, la cual permite visualizar el nivel de agua en el interior del caldero, el encendido y apagado del quemador y la bomba de agua y las alarmas de nivel, presión y temperatura. Las alarmas se activan cuando sobrepasan los límites establecidos o cuando no cumplen con los requerimientos en la programación.es_ES
dc.description.abstractThis work details the rehabilitation and automation of Columbia Boiler CT-6 that is located in the Pilot Plant of the Faculty of Chemical and Agroindustry Engineering of the National Polytechnic School. The Boiler had not worked for 4 years, so it is important study the current status and then perform automation using the elements and parts of the boiler that are in good condition. For example pressure switches, electrodes, manometer are in good conditions in order to guarantee the safety of users. Furthermore, RTD SITRANS TS-500 is located in the Boiler for viewing and monitoring the temperature of the water vapor in real time, and PLC S7-1200 do the control of the boiler. The control interface of the boiler from the workplace of the operator is made in InTouch. It allows the users to view the water level inside the boiler, the switching on/off of the burner, the water pump, and level alarms, pressure and temperature. Alarms are activated when they exceed the established limits, or when they do not meet the requirements in programming.es_ES
dc.description.sponsorshipRodas Benalcázar, Ana Verónica, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2016.es_ES
dc.rightsopenAccess-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectControl automáticoes_ES
dc.subjectElectrónica de instrumentaciónes_ES
dc.titleRehabilitación y automatización del caldero Columbia CT-6 de la planta piloto de Ingeniería Química y Agroindustrial.es_ES
dc.typebachelorThesises_ES
Aparece en las colecciones:Tesis Electrónica y Control (IEC)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CD-6951.pdf15,56 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.