Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/15182
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorOlalla Cambisaca, Walter Stalin-
dc.date.accessioned2016-04-18T20:27:11Z-
dc.date.available2016-04-18T20:27:11Z-
dc.date.issued2016-03-21-
dc.identifier.citationOlalla Cambisaca, W. S. (2016). Inducción electroestática y electromagnética en línea de transmisión doble circuito a 230 kV, Efecto en la operación de seccionadores de puesta a tierra. 77 hojas. Quito : EPN.es_ES
dc.identifier.otherT-IE/4264/CD 6957-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/15182-
dc.descriptionLa inducción electroestática y electromagnética presente en las líneas de transmisión con circuitos múltiples, se debe al acoplamiento mutuo que se da entre ellos, los cuales inducen voltajes y corrientes en los circuitos paralelos desenergizados. Se analizan los efectos que se puede presentar durante las maniobras de cierre y apertura de los seccionadores de puesta a tierra de las líneas de transmisión en los cuales se presentan voltajes y corrientes que fluyen a tierra, que están en función del voltaje y corriente del circuito paralelo energizado. Estos efectos son necesarios considerar para un correcto dimensionamiento de los seccionadores. Se efectúa un análisis de la norma IEC 62271-102 (Alternating current disconnectors and earthing switches), para comprobar el correcto dimensionamiento de los seccionadores de puesta a tierra existentes en las líneas de transmisión, en las cuales se ha efectuado la aplicación. Haciendo uso del programa ATP (Alternative Transients Program), se ha modelado el sistema de transmisión Paute – Pascuales, incluyendo la generación de la central Paute y la carga concentrada en las barras de la subestación Pascuales.es_ES
dc.description.abstractElectrostatic and electromagnetic induction are present in multi circuits transmission lines, due to the mutual coupling between them, which induce voltages and currents in the parallel circuits de-energized. The effects present by closing and opening the earth switches of transmission lines having voltages and currents flowing through the ground, which are a function of the voltage and current of the parallel circuit energized, these being necessary to consider a correct sizing of the earth switches. An analysis was effectuated of standard IEC 62271-102 (Alternating current disconnectors and earthing switches), to verify the correct sizing of the earth switches in the transmission lines, which ones were analyzed. Using the software ATP (Alternative Transients Program), the system of transmission Paute – Pascuales was modeled, including the power station Paute and the load concentrated at the bus bar of the substation Pascuales.es_ES
dc.description.sponsorshipRuales Corrales, Luis Edmundo, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2016.es_ES
dc.rightsopenAccess-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectSistemas eléctricos de potenciaes_ES
dc.subjectLíneas de transmisiónes_ES
dc.subjectElectrostáticaes_ES
dc.titleInducción electroestática y electromagnética en línea de transmisión doble circuito a 230 kV, Efecto en la operación de seccionadores de puesta a tierraes_ES
dc.typebachelorThesises_ES