Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/16315
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorChanatasig Guanoluisa, Luis Eduardo-
dc.date.accessioned2016-06-28T16:40:03Z-
dc.date.available2016-06-28T16:40:03Z-
dc.date.issued2016-05-20-
dc.identifier.citationChanatasig Guanoluisa, L. E. (2016). Coordinación de protecciones de los alimentadores primarios a 13,8 kV de la S/E Pujilí para la Empresa Eléctrica Provincial Cotopaxi. 117 hojas. Quito : EPN.es_ES
dc.identifier.otherT-IE/4303/CD 7135-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/16315-
dc.descriptionEl estudio presenta la coordinación de protecciones de los alimentadores primarios, denominados Pujilí Centro y Pujilí Zumbahua, que abastecen de energía al cantón Pujilí, partiendo de un análisis de las características técnicas y eléctricas de los alimentadores en estudio, se describe la metodología empleada para la coordinación entre cada elemento y equipo de protección instalados en todo el sistema, y los tipos de fallas a los cuales están expuestos. Los estudios de flujos de potencia y corrientes de cortocircuitos necesarios para el estudio, se realizaron con los programas computacionales CYMDIST y CYMTCC, obteniendo como resultado un sistema de protecciones confiable, sensible, selectivo y rápido, ante la presencia de fallas; reduciendo las operaciones no deseadas y mejorando la continuidad de servicio a los usuarios.es_ES
dc.description.abstractThe study provides the protection coordination of primary feeders, named Pujilí Centro and Pujilí Zumbahua, supplying energy to Pujilí, based on an analysis of the technical and electrical characteristic of the feeders in study, describes the methodology used for coordination between each element and protective equipment installed throughout the system, and the types of faults to which they are exposed. Studies of power flow and short circuit currents required for the study were performed using computer programs CYMDIST and CYMTCC, resulting in a reliable, sensitive, selective and fast protection, in the presence of faults; reducing unwanted operations and improving continuity of service to users.es_ES
dc.description.sponsorshipRuales Corrales, Luis Edmundo, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2016.es_ES
dc.rightsopenAccess-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectProtecciones eléctricases_ES
dc.subjectVoltajees_ES
dc.subjectSistemas de distribuciónes_ES
dc.titleCoordinación de protecciones de los alimentadores primarios a 13,8 kV de la S/E Pujilí para la Empresa Eléctrica Provincial Cotopaxies_ES
dc.typebachelorThesises_ES
Aparece en las colecciones:Tesis Ingeniería Eléctrica (IE)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CD-7135.pdf11,81 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.