Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/16624
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorChávez Recalde, Diego Fernando-
dc.date.accessioned2016-08-23T21:03:24Z-
dc.date.available2016-08-23T21:03:24Z-
dc.date.issued2016-08-24-
dc.identifier.citationChávez Recalde, D. F. (2016). Desarrollo de un software para la detección y ubicación de fallas en un sistema eléctrico de potencia usando el módulo DPL de DIg SILENT PowerFactory. 152 hojas. Quito : EPN.es_ES
dc.identifier.otherT-IE/4330/CD 7253-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/16624-
dc.descriptionEl sistema eléctrico de potencia (SEP) permite la transferencia de energía eléctrica desde las fuentes de generación hacia los centros de carga. Fallas en el SEP alteran las condiciones operativas y eventualmente podrían provocar la inestabilidad del sistema o la interrupción del servicio de energía eléctrica. Existen equipos que permiten tomar ciertas mediciones, las cuales resultan ser necesarias para el análisis operativo y de eventos de falla en tiempo real. La aplicación de la tecnología fasorial ofrece nuevas posibilidades para la supervisión, protección, análisis y control del SEP. En este proyecto se implementa un algoritmo para la localización de fallas usando datos fasoriales, el cual permite mejorar los métodos tradicionales. El algoritmo implementado distingue las respuestas de varios modelos linealizados frente a las mediciones realizadas ante un transitorio en el SEP. En base a esto, un detector de Máxima Probabilidad A-posteriori (MAP) es implementado, el cual se basa en la inferencia estadística de varias hipótesis que determinan la probabilidad de ocurrencia de falla. El algoritmo se implementa en el módulo DPL del software PowerFactory de DIgSILENT. Las distintas pruebas realizadas demuestran que el software es capaz de escoger la hipótesis más probable entre una lista de posibles hipótesis.es_ES
dc.description.abstractThe electric power system (EPS) allows to transfer power from generation sources to load centers. The failures in the system alter the operating conditions and could eventually lead to system instability or interruption of electricity service. There are equipment that allow to take certain measurements, which prove to be necessary for operational analysis and of fault events in real time. The application of the phasor technology offers new possibilities for monitoring, protection, analysis and control of the EPS. In this project, an algorithm is implemented to localize a failure using phasor data, which improves traditional methods. The implemented algorithm distinguishes responses of several linearized models against measurements mode during the transient response after the failure. Based on this, a Maximum Likelihood A-posteriori (MAP) detector is implemented, which uses statistical inference from several hypotheses to determine the probability of a failure from the measurements. The algorithm is implemented in the DPL software module PowerFactory DIgSILENT. The different experiments prove that the developed software is able to distinguish the most likely scenario from a list of possible scenarioses_ES
dc.description.sponsorshipAbad Torres, Jackeline, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2016.es_ES
dc.rightsopenAccess-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectSistemas eléctricos de potenciaes_ES
dc.subjectSistemas de protecciónes_ES
dc.titleDesarrollo de un software para la detección y ubicación de fallas en un sistema eléctrico de potencia usando el módulo DPL de DIg SILENT PowerFactoryes_ES
dc.typebachelorThesises_ES
Aparece en las colecciones:Tesis Ingeniería Eléctrica (IE)