Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/16776
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorBenítez Avalos, Holguer Gabriel-
dc.contributor.authorLascano Medina, Gustavo Iván-
dc.date.accessioned2016-10-31T22:27:02Z-
dc.date.available2016-10-31T22:27:02Z-
dc.date.issued2016-10-26-
dc.identifier.citationBenítez Avalos, H. G., & Lascano Medina, G. I. (2016). Ensayo experimental de columnas compuestas cuadradas no compactas sometidas a fuerza axial. 151 hojas. Quito : EPN.es_ES
dc.identifier.otherT-IC/0731/CD 7370-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/16776-
dc.descriptionLas estructuras que se construyen son diseñadas por varios métodos y uno de ellos es la construcción con elementos compuestos los mismos que están formados por perfiles de acero ahogados en concreto reforzado, así como perfiles tubulares rellenos de concreto. En este trabajo se ensayará columnas tubulares rellenas de hormigón, se inició con la construcción de 14 probetas las cuales son 7 secciones diferentes en total 2 probetas por cada sección, todas las probetas tienen una altura de 1.40 metros, se consideró esta altura ya que el ensayo solo consiste en someter a las probetas a carga axial de compresión. Se planteó las secciones con el objetivo de obtener elementos no compactos cuadrados. Los ensayos se basaron en aplicar una carga puntual direccionada axialmente en toda el área transversal de las columnas tanto superior como inferior mediante placas de sujeción, las mismas que ejercieron presión a compresión a través de un gato hidráulico. El ensayo consistió en aplicar cargas cíclicas a las columnas hasta que estas fallen obteniendo así una curva de histéresis en la que se analiza la carga crítica de pandeo, capacidad nominal experimental y la capacidad máxima, además el análisis de pandeo local de todas las probetas.es_ES
dc.description.abstractThe structures built are designed by various methods and one of them is the construction thereof with composite elements which are formed by steel profiles drowned in reinforced concrete and concrete filled hollow section. In this paper filled tubular concrete columns were tested, began with the construction of 14 specimens which are 7 different sections in total of 2 samples per section, all specimens have a height of 1.40 meters, it was considered this point as the test only involves subjecting the samples to axial compression load. Sections in order to obtain non compact raised square elements. The tests were based on a point load applied axially directed entire cross section of both the top and bottom columns by clamping plates, the same compressive pressure exerted by a hydraulic jack. The test consisted of applying cyclic loads to the columns until they fail thus obtaining a hysteresis curve in which the critical buckling load, experimental rated capacity and maximum, plus analysis of local buckling of all specimens capacity is analyzed.es_ES
dc.description.sponsorshipVintimilla Jaramillo, Jorge Ricardo, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2016.es_ES
dc.rightsopenAccess-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectESTRUCTURAS (CONSTRUCCIÓN)es_ES
dc.subjectHORMIGONESes_ES
dc.titleEnsayo experimental de columnas compuestas cuadradas no compactas sometidas a fuerza axiales_ES
dc.typebachelorThesises_ES
Aparece en las colecciones:Tesis Ingenieria Civil y Ambiental (ICA)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CD-7370.pdf44,35 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.