Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/17013
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorMora Miñaca, Cristian Alexander-
dc.date.accessioned2017-01-23T20:53:29Z-
dc.date.available2017-01-23T20:53:29Z-
dc.date.issued2017-01-03-
dc.identifier.citationMora Miñaca, C. A. (2017). Metodología para el dimensionamiento eléctrico de reactores de potencia incorporados en líneas de 500 kV del sistema nacional de transmisión. 190 hojas. Quito : EPN.es_ES
dc.identifier.otherT-IE/4400/CD 7593-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/17013-
dc.descriptionEn un sistema de transmisión de extra - alto voltaje (EAV), generalmente se tienen voltajes en líneas y barras de subestaciones por encima de los límites permitidos de operación, por esta razón, se incorporan medios de compensación, para controlar los perfiles de voltaje. El presente trabajo tiene como finalidad aplicar una metodología, la cual se empleé en el dimensionamiento de reactores de potencia como elementos de compensación reactiva. Para el efecto, se ha modelado en el programa computacional Power Factory, el Sistema Nacional de Transmisión a 500 kV con la incorporación de los reactores de potencia en las líneas de transmisión. Con esto se realizan estudios en estado estable y transitorio para comprobar la influencia de los reactores en el control de los perfiles de voltaje. Los estudios realizados se han analizado en escenario seco y lluvioso, en tres casos de estudio: demanda mínima, demanda media, y demanda máxima. Finalmente se presentan los resultados obtenidos mediante simulaciones realizadas en Power Factory, con las debidas justificaciones, conclusiones y recomendaciones.es_ES
dc.description.abstractIn an extra-high voltage (EHV) transmission system, generally the voltages of lines and substations bars are above the permitted limits of operation, due this fact, compensation devices are incorporated to control of the voltage profiles. The purpose of this work is to apply a methodology , which is used in the dimensioning of power reactors as devices of reactive compensation. In this way, the national transmission system at 500 kV has been modeled in the PowerFactory software including the connection of the power reactors in the transmission lines. Once upon done this, steady-state and transient-state studies are carried out to verify the influence of the power reactors in the control of the voltage profiles. The studies performed have been analyzed in dry and rainy stage, in three studies cases: minimum demand, average demand, and maximum demand. Finally, the results obtained by simulations carried out in Power Factory are presented, with the due justifications, conclusions and recommendations.es_ES
dc.description.sponsorshipPérez Yauli, Fabián Ernesto, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2017.es_ES
dc.rightsopenAccess-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectSISTEMAS ELECTRICOS DE POTENCIAes_ES
dc.subjectALTO VOLTAJEes_ES
dc.subjectLINEAS DE TRANSMISIONes_ES
dc.titleMetodología para el dimensionamiento eléctrico de reactores de potencia incorporados en líneas de 500 kV del sistema nacional de transmisiónes_ES
dc.typebachelorThesises_ES
Aparece en las colecciones:Tesis Ingeniería Eléctrica (IE)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CD-7593.pdf8,14 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.