Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/17096
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorPazmiño Linzán, Maritza Alexandra-
dc.date.accessioned2017-03-14T21:19:34Z-
dc.date.available2017-03-14T21:19:34Z-
dc.date.issued2017-03-10-
dc.identifier.citationPazmiño Linzán, M. A. (2017). Implementación de un plan de emergencia en la estación de servicio Petrocomercial Ponceano. 163 hojas. Quito : EPN.es_ES
dc.identifier.otherT-MVE/0501/CD 7669-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/17096-
dc.descriptionEl desarrollo del presente plan de emergencia contra incendios se realizó en la estación de servicio Petrocomercial Ponceano de EP PETROECUADOR, para cumplir con normativa aplicable, disminuir riesgos y mejorar las condiciones de seguridad y salud ocupacional de los trabajadores. En el recorrido por la instalación, se aplicó los check list del Cuerpo de Bomberos del Distrito Metropolitano de Quito y de la estación, en el cual se evidencio hallazgos, que permitió implementar los medios de prevención y control en la estación, asimismo se realizó la evaluación de riesgos mediante el método Meseri, se determinó el tipo de construcción, situación, ubicación, propagabilidad y destructibilidad, se valoró cualitativa y cuantitativamente el riesgo. Posteriormente se elaboró el mapa de riesgos, se capacitó al personal en manejo de extintores, uso de mangueras, posterior a esta metodología se establecieron situaciones de emergencia en la estación, las cuales fueron evaluadas y se aplicaron controles obligatorios para evitar, eliminar y vigilar los factores de riesgos identificados. Se formó brigadas con funciones y responsabilidades de cada funcionario; además, de planes de acción de acuerdo a la emergencia, en la que constan los medios de comunicación, número de emergencia de personal interno y entidades externas de apoyo.es_ES
dc.description.abstractThe development of the present fire emergency plan was carried out at the Petrocomercial Ponceano service station of EP PETROECUADOR, for the compliment with applicable regulations, reducing risks and improve the occupational safety and health conditions of workers. In the tour of the installtion, the checklist of the Fire Department of the Metropolitan District of Quito and of the station was applied, in which evidence was found, who made possible to implement the measures of prevention and control in the station, The risk assessment was also carried out using the Meseri method, it was determined the type of construction, situation, location, propagability and destructibility were determined and the risk was assessed qualitative and quantitatively. Subsequently the risk map was elaborated, personnel were trained in fire extinguisher management, use of hoses, Following this methodology emergency situations were established at the station, whom were evaluated and mandatory controls were applied to avoid, eliminate and monitor the Identified risk factors. Brigades were formed with roles and responsibilities of each officer; besides, action plans according to the emergency, which include the media, emergency number of internal staff and external support entities.es_ES
dc.description.sponsorshipMoreno Aviles, Julia María, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2017.es_ES
dc.rightsopenAccess-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectSEGURIDAD INDUSTRIALes_ES
dc.subjectSALUD OCUPACIONALes_ES
dc.titleImplementación de un plan de emergencia en la estación de servicio Petrocomercial Ponceanoes_ES
dc.typemasterThesises_ES
Aparece en las colecciones:Tesis Maestría en Seguridad Industrial y Salud Ocupacional (FIQA)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CD-7669.pdf15,04 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.