Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/17251
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorCórdova Bravo, Jorge Arturo-
dc.date.accessioned2017-04-27T21:27:32Z-
dc.date.available2017-04-27T21:27:32Z-
dc.date.issued2017-04-26-
dc.identifier.citationCórdova Bravo, J. A. (2017). Diseño e implementación de un sistema automático de adquisición de datos para medición de la concentración de co2 disuelto en fuentes naturales de agua. 147 hojas. Quito : EPN.es_ES
dc.identifier.issnT-IE/4431/CD 7753-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/17251-
dc.descriptionEn este trabajo se presenta la implementación de un sistema automático para la medición de la variación de la concentración de CO2 disuelto en las fuentes naturales de agua cercanas a volcanes, el mismo que se basa en la técnica de detección por absorción en el espectro infrarrojo. Este sistema ha sido desarrollado con el objetivo de mejorar la vigilancia volcánica por parte del IG-EPN. Las pruebas de campo para validar el funcionamiento del sistema, se realizaron en las fuentes Palmira que se origina en la base del volcán Guagua Pichincha y en la fuente Santa Ana que se origina en el volcán Tungurahua, donde se obtuvieron valores de concentración de 22,6% y 22,2% respectivamente. Estos valores son muy similares con los obtenidos en otro trabajo previo, en el cual se realizó el análisis con otra técnica valida. Consecuentemente se demuestra que es posible confiar en los datos proporcionados por el sistema para la monitorización de la actividad volcánica.es_ES
dc.description.abstractThis work presents the implementation of an automatic system designed to measure the concentration of dissolved CO2 in natural springs near associated to volcanoes. The instrument is based on the infrared spectrum absorption detection technique. This system has been developed to improve volcanic surveillance by IG-EPN. Field tests to validate the operation of the system were performed at the Palmira spring which originates at the base of Guagua Pichincha volcano as well as at Santa Ana source at the base of Tungurahua volcano. As a result we obtained concentration values of 22, 6% and 22.2% respectively. These values are very similar to those presented in previous work whose analysis was performed by gas chromatography. Consequently, including the data provided by this system in the routine monitoring of volcanic activity is possiblees_ES
dc.description.sponsorshipHidalgo Trujillo, Silvana Ivonne, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2017.es_ES
dc.rightsopenAccesses_ES
dc.subjectCONTROL AUTOMÁTICOes_ES
dc.subjectMICROCONTROLADORESes_ES
dc.subjectAPLICACIONES DE COMPUTADORes_ES
dc.titleDiseño e implementación de un sistema automático de adquisición de datos para medición de la concentración de co2 disuelto en fuentes naturales de aguaes_ES
dc.typebachelorThesises_ES
Aparece en las colecciones:Tesis Electrónica y Control (IEC)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CD-7753.pdf50,89 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.