dc.identifier.citationAlbuja Espinosa, L. A., & Soria Acosta, P. D. (2017). Elaboración de un sistema de gestión energética para el hospital Baca Ortiz de Quito, según normativa INEN NTE ISO 50001. 352 hojas. Quito : EPN.es_ES
dc.identifier.otherT-MVE/0607/CD 8235-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/18844-
dc.descriptionSe desarrolla un sistema de gestión energética (SGEn), aplicado al modelo institucional del Hospital Baca Ortiz de Quito, fundamentado en la aplicación de la norma INEN NTE ISO 50001, se determinó, definió los requisitos y documentación necesaria para la aplicación del SGEn, presenta los procesos que son necesarios para ajustarse a la norma y proporcionar una guía general para establecer responsabilidades y niveles de gestión, políticas energéticas, planes de acción para alcanzar metas energéticas, planificación de la implementación y ejecución del SGEn, etc. Se realizó una auditoría energética de los diferentes tipos de energía primaria así como los principales usos finales, los combustibles fósiles representan el 56.01 % y la electricidad el 43.99 %, se identificó los sistemas energéticos de mayor relevancia, así como los siguientes indicadores más relevantes, energía térmica 203.45 kWh/m² y 15.24 kWh/cama; la energía eléctrica 259.06 kWh/m² y 19.41 kWh/cama; además se determinó las oportunidades de ahorro de energía anual, en 479.06 MWh y 23833.19 USD, la reducción de emisiones anual en 1078.10 [Ton CO2/MWh]. La implementación, verificación y acción del SGEn es responsabilidad de la alta dirección del hospital, aunque existe el interés de la Institución descrito en el Anexo A del presente proyecto.es_ES
dc.description.abstractAn energy management system (SGEn) was applied to the institutional model of the Baca Ortiz Hospital in Quito, based on the INEN NTE ISO 50001 standard, defined the requirements and documentation necessary for the application of the SGEn, we presents the processes that are necessary to conform to the norm and provide a general guide to establish responsibilities and levels of management, energy policies, action plans to achieve energy goals, planning the implementation and execution of the SGEn, etc. An energy audit was carried out of the different types of primary energy as well as the main end uses, fossil fuels represent 56.01% and electricity 43.99%, the most relevant energy systems were identified, as well as the following most relevant indicators, thermal energy 203.45 kWh / m² and 15.24 kWh / bed; electric power 259.06 kWh / m² and 19.41 kWh / bed; In addition, annual energy savings opportunities were estimated at 479.06 MWh and 23833.19 USD, the annual emission reduction at 1078.10 [Ton CO2 / MWh]. The implementation, verification and action of the SGEn is responsibility of the senior management of the hospital, although there is the interest of the Institution described in Annex A of this project.es_ES
dc.description.sponsorshipHidalgo Diaz, Víctor Hugo, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2017.es_ES
dc.rightsopenAccesses_ES
dc.subjectSISTEMAS ENERGÉTICOSes_ES
dc.subjectTERMODINÁMICAes_ES
dc.subjectTRANSFERENCIA DE CALORes_ES
dc.titleElaboración de un sistema de gestión energética para el hospital Baca Ortiz de Quito, según normativa INEN NTE ISO 50001es_ES