Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/18988
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorCárdenas Ramos, Edwin Javier-
dc.contributor.authorFernández Jiménez, Daniel Efraín-
dc.date.accessioned2017-12-11T18:51:38Z-
dc.date.available2017-12-11T18:51:38Z-
dc.date.issued2017-12-11-
dc.identifier.citationCárdenas Ramos, E. J., & Fernández Jiménez, D. E. (2017). Estudio de la influencia del factor de forma sobre la temperatura operativa de edificaciones en la ciudad de Quito, mediante simulación en EnergyPlus. 107 hojas. Quito : EPN.es_ES
dc.identifier.otherT-MVE/0628/CD 8285-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/18988-
dc.descriptionEste estudio pretende determinar la influencia del factor de forma sobre el comportamiento térmico de edificaciones residenciales de la ciudad de Quito, mediante simulación energética en EnergyPlus. El comportamiento térmico se evaluará con la temperatura operativa y como función objetivo el disconfort térmico. De acuerdo a la normativa ASHRAE 55 se establece el rango de confort para la ciudad de Quito y se evalúa en escenarios monozonales y multizonales mediante análisis estadísticos de las temperaturas operativas, para edificaciones residenciales en función del disconfort. Para la modelación monozonal se establecen dos análisis, en el primero se determina que la forma geométrica del edificio (cuadrada, rectangular, forma L y forma U) y el factor de forma no tienen un impacto significativo en relación a la temperatura operativa y al disconfort de las edificaciones; y, en el segundo se evidencia que la influencia del factor de forma sobre la función objetivo (disconfort) viene dada por la incidencia de la radiación solar sobre las superficies de la edificación que cuentan con una mayor área expuesta hacia el Oeste-Este. En el caso multizonal se realiza la modelación de una edificación rectangular con cinco zonas internas, en este análisis se determina que el factor de forma tiene una baja incidencia en el comportamiento térmico de la edificación y que las condiciones de borde, orientación y el acristalamiento del edificio tienen una mayor influencia en el confort y la temperatura operativa interna de la edificación.es_ES
dc.description.abstractThis study aims to determine the influence of the shape factor over the thermal behavior of residential buildings in the city of Quito, through energy simulation in EnergyPlus. The thermal behavior will be evaluated with the operative temperature and as an objective function the thermal discomfort. According to the ASHRAE 55 regulation, the comfort range for the city of Quito is established and is evaluated in single-zone and multizonal scenarios through statistical analysis of operative temperatures for residential buildings based on discomfort. For the monozonal modeling, two analyzes are established, in the first one it is determined that the geometrical shape of the building (square, rectangular, form L and form U) and the form factor do not have a significant impact in relation to the operative temperature and discomfort of the buildings; and, in the second, it is evident that the influence of the shape factor on the objective function (discomfort) is given by the incidence of solar radiation on the building surfaces that have a greater area exposed to the West-East. In the multizonal case, the modeling of a rectangular building with five internal zones is performed, in this analysis it is determined that the shape factor has a low incidence in the thermal behavior of the building and that the conditions of edge, orientation and glazing of the building have a greater influence on the comfort and internal operative temperature of the building.es_ES
dc.description.sponsorshipOrdóñez Malla, Freddy, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2017.es_ES
dc.rightsopenAccesses_ES
dc.subjectEFICIENCIA ENERGÉTICAes_ES
dc.subjectENERGÍAes_ES
dc.subjectAPLICACIONES DE COMPUTADORes_ES
dc.titleEstudio de la influencia del factor de forma sobre la temperatura operativa de edificaciones en la ciudad de Quito, mediante simulación en EnergyPluses_ES
dc.typemasterThesises_ES
Aparece en las colecciones:Tesis Maestría en Eficiencia Energética (FIM)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CD-8385.pdf2,99 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.