dc.contributor.authorPallaroso Yela, Mayra Alejandra-
dc.date.accessioned2018-06-25T22:14:48Z-
dc.date.available2018-06-25T22:14:48Z-
dc.date.issued2018-06-25-
dc.identifier.citationPallaroso Yela, M. A. (2018). Efecto del material de contraste en las distribuciones de dosis asociadas a la braquiterapia de alta tasa con Iridio-192 para tratamientos del cáncer cérvico-uterino. 73 hojas. Quito : EPN.es_ES
dc.identifier.otherT-MVE/0681/CD 8888-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/19490-
dc.descriptionEn este trabajo se cuantificó el efecto que produce el material de contraste en las distribuciones de dosis asociadas a tratamientos del cáncer cérvico-uterino con braquiterapia de alta tasa de dosis, con Iridio-192. El efecto se evidenció mediante el cálculo de dosis, con el algoritmo Acuros implementado en el sistema de planificación Brachyvision. Para los cálculos se identificaron los números CT (unidades Hounsfield) asociados a la densidad electrónica de la vejiga con diferentes concentraciones de contraste, las cuales fueron desde 0 % (0 HU, equivalente a agua) hasta 10% (316.18 ± 94 HU) y se localizaron 236 puntos alrededor del implante, de los cuales 41 estuvieron dentro de la vejiga, para cada punto se calculó la desviación de la dosis en presencia de contraste en la vejiga respecto a la dosis en presencia de agua. Para 500 HU, las desviaciones fueron hasta 0.10% para los puntos fuera de la vejiga y hasta 2.21% en los puntos dentro de la vejiga. Para el 8%, concentración óptima para la imagen, en un volumen de 2 cm3 de la vejiga, sería hasta 0.44% mayor dosis. El aumento de dosis encontrado en este estudio está dentro de las tolerancias establecidas en radioterapia.es_ES
dc.description.abstractThe effect in the doses distributions associated to cervical-uterine cancer treatments with high dose rate brachytherapy with Iridium-192 produced by the contrast material was quantified. This was done by the calculation of doses with the Acuros algorithm implemented in the Brachyvision planning system. For the calculations the CT numbers (Hounsfield units) associated with the electronic density of the bladder with different concentrations of contrast were identified which were from 0 % (0 HU, equivalent to water) to 10 % (316.18 ± 94 HU) and 236 points around the implant were located, 41 of which were inside the bladder. For each of these points the deviation of the dose was calculated in the presence of contrast in the bladder with respect to the dose in the presence of water. For 500 HU, the deviations were up to 0.10 % for points outside the bladder and up to 2.21 % for points within the bladder. For the optimum concentration for imaging of 8 %, the absorbed dose in a volume of 2 cm3 of the bladder, would be up to 0.44 % higher dose than dose for water. The increment in absorbed dose lies within the tolerances established in radiotherapy.es_ES
dc.description.sponsorshipBayas Rea, Marco Vinicio, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2018.es_ES
dc.rightsopenAccesses_ES
dc.subjectDOSIMETRÍAes_ES
dc.subjectFÍSICAes_ES
dc.subjectRADIACIONES IONIZANTESes_ES
dc.titleEfecto del material de contraste en las distribuciones de dosis asociadas a la braquiterapia de alta tasa con Iridio-192 para tratamientos del cáncer cérvico-uterinoes_ES
dc.typemasterThesises_ES