Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/21117
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorRiascos Barrazueta, Felipe David-
dc.date.accessioned2020-10-08T20:09:55Z-
dc.date.available2020-10-08T20:09:55Z-
dc.date.issued2020-08-25-
dc.identifier.citationRiascos Barrazueta, F. D. (2020). Modelación matemática de los sistemas de control de velocidad de unidades de la central hidroeléctrica Coca Codo Sinclair. 189 hojas. Quito : EPN.es_ES
dc.identifier.otherT-IE 5081/CD 10594-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/21117-
dc.descriptionEn el presente estudio, se desarrolló un proceso de modelación y validación de parámetros del sistema de control de velocidad, regulador y turbina, de las unidades de generación de la central hidroeléctrica Coca Codo Sinclair. Para este propósito, se utiliza la potencialidad del software DIgSILENT PowerFactory para implementar los bloques de funciones de transferencia. Posteriormente, el modelo se valida a través de la identificación paramétrica utilizando el algoritmo heurístico de optimización mapeo de media-varianza MVMO, sobre la base de registros obtenidos a través de unidades de medición fasorial (PMU) de un evento en tiempo real que ocurrió en el Sistema Nacional Interconectado (SNI). Para desarrollar el modelo en este estudio, se analizaron tres tipos de turbina Pelton y modelos de regulador de velocidad con diferente complejidad. La disponibilidad de un modelo validado y probado del sistema de control de velocidad de generadores garantizará simulaciones suficientemente precisas que representen con minuciosidad el comportamiento real de la central hidroeléctrica, lo cual es una premisa importante para la toma de decisiones adecuadas en relación con las acciones de control.es_ES
dc.description.abstractIn the present study, a process for modeling and validation of parameters of the speed control system, governor and turbine, from the generation units of Coca Codo Sinclair hydroelectric power plant was developed. For this purpose, the potentiality of DIgSILENT PowerFactory software is used to implement the transfer function blocks. Subsequently, the model is validated through parameter identification using the heuristic algorithm mean-variance mapping optimization (MVMO), based on records obtained through phasor measurement units (PMU) of a real-time event that occurred in the National Interconnected System (SNI). To develop the model in this study, three types of Pelton turbine and speed regulator models with different complexity were analyzed. The availability of a validated and tested model of the generator speed control system will guarantee sufficiently precise simulations that accurately represent the real behavior of the hydroelectric power plant, which is an important premise for making adequate decisions in relation to control actions.es_ES
dc.description.sponsorshipCepeda Campaña, Jaime Cristóbal, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2020.es_ES
dc.rightsopenAccesses_ES
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectSISTEMAS ELÉCTRICOSes_ES
dc.subjectREGULADOR DE VELOCIDADes_ES
dc.subjectMODELACIÓNes_ES
dc.titleModelación matemática de los sistemas de control de velocidad de unidades de la central hidroeléctrica Coca Codo Sinclaires_ES
dc.typebachelorThesises_ES
Aparece en las colecciones:Tesis Ingeniería Eléctrica (IE)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CD 10594.pdf9,28 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.