DC Field | Value | Language |
---|---|---|
dc.contributor.author | Quinteros Hidalgo, Dayán Humberto | - |
dc.date.accessioned | 2022-02-07T14:14:29Z | - |
dc.date.available | 2022-02-07T14:14:29Z | - |
dc.date.issued | 2022-02-07 | - |
dc.identifier.citation | Quinteros Hidalgo, D. H. (2022). Diseño e implementación de un filtro pasivo shunt multietapa resonante para la mitigación de armónicos producidos por una carga no lineal. 114 hojas. Quito : EPN. | es_ES |
dc.identifier.other | T-IE/5276/CD 11621 | - |
dc.identifier.uri | http://bibdigital.epn.edu.ec/handle/15000/22129 | - |
dc.description | Esta investigación aborda una de las soluciones que existen para resolver los problemas relacionados con la distorsión de la onda de corriente en un sistema eléctrico debido al efecto que produce la operación de una carga no lineal, afectando así también a la onda de voltaje. En primera instancia se investigó la producción del contenido armónico asociado a la carga y así se logró implementar un sistema eléctrico con un THD de corriente del 200 %. Para la reducción de esta distorsión se investigó e implementó un sistema de filtrado basado en la operación en conjunto de elementos pasivos para que de esta manera se alcance la resonancia paralela al sistema eléctrico contaminado, creando así un camino de muy baja impedancia a frecuencias armónicas de orden 3, 5 y 7. La metodología de la investigación implica la programación, simulación, implementación y las pruebas experimentales realizadas que se asocian al sistema eléctrico creado. Resultando de esta forma en una reducción importante del THD de corriente cuyo valor bajó al 50 %. | es_ES |
dc.description.abstract | This research content one of the solutions that exist to solve problems related to current waveform distortion due to effect produced by the non-linear load operation, which also affects to voltage waveform. At first, the harmonic content generation related to load was researched and an electrical system with a 200 % THD value was achieved. To reduce this distortion, a system filtering based on the passive elements operation was researched and implemented; in this way the shunt resonance to contaminated electrical system was obtained to generate a low impedance path to 3rd, 5thand 7th harmonic frequencies order. The research methodology implies the programming, simulation, implementation and experimental tests associated with the electrical system previously created. Therefore an important THD reduction was obtained because its value fell to 50 %. | es_ES |
dc.description.sponsorship | Salazar Yépez, Gabriel Benjamín, director | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Quito, 2022 | es_ES |
dc.rights | openAccess | es_ES |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | - |
dc.subject | ENERGÍA ELÉCTRICA | es_ES |
dc.subject | CONSERVACIÓN DE LA ENERGÍA | es_ES |
dc.subject | INFORMACIÓN ENERGÉTICA | es_ES |
dc.title | Diseño e implementación de un filtro pasivo shunt multietapa resonante para la mitigación de armónicos producidos por una carga no lineal. | es_ES |
dc.type | bachelorThesis | es_ES |
Appears in Collections: | Tesis Ingeniería Eléctrica (IE) |
Files in This Item:
File | Description | Size | Format | |
---|---|---|---|---|
CD 11621.pdf | 7,01 MB | Adobe PDF | View/Open |