dc.contributor.authorRamón Sosoranga, Freddy Kevin-
dc.date.accessioned2022-06-22T21:33:35Z-
dc.date.available2022-06-22T21:33:35Z-
dc.date.issued2022-06-06-
dc.identifier.citationRamón Sosoranga, F. K. (2022). Análisis de las condiciones funcionales para operación normal del anillo a 69 kV que dota de energía a la ciudad de Machala. 220 páginas. Quito : EPN.es_ES
dc.identifier.otherT-IE 5455/CD 12229-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/22557-
dc.descriptionSe analizaron los problemas que presenta el anillo a 69 kV que dota de energía eléctrica a la ciudad de Machala, además, se efectuó el levantamiento de información con respecto al sistema de subtransmisión para la correspondiente modelación permitiendo la simulación del cambio de topología desde una configuración radial a una configuración en anillo. Por medio del análisis realizado mediante los estudios de flujos de potencia, análisis de contingencias con observación de niveles de corriente, cargabilidad, perfiles de voltaje, pérdidas, entre otros., permitieron la especificación de elementos y dispositivos que precisan un cambio o repotenciación para el mejoramiento y operación normal del sistema. No obstante, los ajustes y coordinación de las protecciones son necesarias para un sistema cuya topología corresponde a una configuración en anillo. Las protecciones como los relés diferenciales analizados permiten una mayor confiabilidad, rapidez, selectividad frente a fallas en líneas actuando de forma instantánea dentro del área o zona de protección. Los ajustes de las protecciones de sobrecorriente típicas que se encuentran instalados en la actualidad corresponden a un análisis convencional cuyo sistema se trata de una configuración radial, siendo necesario el cambio de estos relés por relés de sobrecorriente direccional.es_ES
dc.description.abstractThe problems presented by the 69 kV ring that provides electric power to the city of Machala were analyzed, in addition, the information regarding the subtransmission system was collected for the corresponding modeling allowing the simulation of the topology change from a radial configuration to a ring configuration. Through the analysis carried out by means of power flow studies, contingency analysis with observation of current levels, loadability, voltage profiles, losses, among others, allowed the specification of elements and devices that require a change or repowering for the improvement and normal operation of the system. However, the adjustments and coordination of the protections are necessary for a system whose topology corresponds to a ring configuration. Protections such as the differential relays analyzed allow greater reliability, speed and selectivity in the event of line faults, acting instantaneously within the protection area or zone. The settings of the typical overcurrent protections that are currently installed correspond to a conventional analysis whose system is a radial configuration, being necessary to change these relays for directional overcurrent relays.es_ES
dc.description.sponsorshipLucio Castro, Miguel Angel, director.es_ES
dc.language.isospaes_ES
dc.publisherQuito : EPN, 2022es_ES
dc.rightsopenAccesses_ES
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectANILLO ELÉCTRICOes_ES
dc.subjectRELÉ DIFERENCIALes_ES
dc.subjectMACHALAes_ES
dc.subjectPROTECCIONES ELÉCTRICASes_ES
dc.subjectDISTRIBUCIÓN DE ENERGÍAes_ES
dc.titleAnálisis de las condiciones funcionales para operación normal del anillo a 69 kV que dota de energía a la ciudad de Machala.es_ES
dc.typebachelorThesises_ES