Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/24764
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorEnríquez Fuenmayor, Christian Andrés-
dc.contributor.authorSalazar Cedeño, María Belén-
dc.date.accessioned2023-08-16T13:12:30Z-
dc.date.available2023-08-16T13:12:30Z-
dc.date.issued2023-06-
dc.identifier.citationEnríquez Fuenmayor, C.A. / Salazar Cedeño, M.B. (2023). Análisis de parámetros dimensionales en la aireación de chorros rectangulares turbulentos de vertido libre por coronación de presas. 56 páginas. Quito : EPN.es_ES
dc.identifier.otherT-MVE-1044/CD 13479-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/24764-
dc.descriptionEl presente documento tiene por objetivo dar a conocer una comparación de resultados obtenidos en el estudio del caso de “Análisis de parámetros dimensionales en la aireación de chorros rectangulares turbulentos de vertido libre por coronación de presas”, para el cual se planteó simular numéricamente flujos bifásicos en 2D y 3D con altas concentraciones de aire en chorros de vertido libre con software CFD ANSYS FLUENT. En concordancia con este análisis, se planteó el estudio de la caída del chorro en una paramétrica de 1 hasta 2 metros y un ancho de 1.05 metros; lo expuesto, con la finalidad de evaluar mediante simulaciones numéricas, previo al ajuste de parámetros en la definición del mallado, las propiedades bifásicas (aire + agua) y definir el modelo de turbulencia adecuado para resolver el problema, velocidades y el grado de disipación de energía del chorro (mediante la verificación de la fracción de volumen), ya que con los resultados se logró en una primera instancia, comprender con mayor profundidad los mecanismos de disipación de energía en chorros y apoyar con criterios de diseño hidráulico a los ingenieros de presas, y posteriormente se hizo una comparación con los resultados de laboratorio obtenidos en el trabajo doctoral de Ortega (2022) para caudales de 0,024 m3/s/m, 0,048 m3/s/m y 0,096 m3/s/m.es_ES
dc.description.abstractThe objective of this document is to present a comparison between the results obtained in this case of study called "Analysis of dimensional parameters in the aeration of turbulent rectangular jets of free discharge by crowning dams", for which it was proposed a numerically simulate of biphasic flows in 2D and 3D with high concentrations of air in free discharge jets with CFD ANSYS FLUENT software. In accordance with this analysis, the study of the fall of the jet was proposed in a parametric of 1 to 2 meters and a width of 1.05 meters; Furthermore, in order to evaluate by means of numerical simulations, prior to the adjustment of parameters in the definition of the mesh, the biphasic properties (air + water) and define the appropriate turbulence model to solve the problem, speeds and the degree of dissipation of energy of the jet (through the verification of the volume fraction), since with the results it was achieved in a first instance, to understand the mechanisms of energy dissipation in jets and to support dam engineers with hydraulic design criteria , and later, a comparison was made with the laboratory results obtained in Ortega's (2022) doctoral work.es_ES
dc.language.isospaes_ES
dc.publisherQuito : EPN, 2023.es_ES
dc.rightsopenAccesses_ES
dc.subjectMECÁNICAes_ES
dc.subjectDISEÑOes_ES
dc.subjectSIMULACIÓNes_ES
dc.subjectAIREACCIÓNes_ES
dc.subjectCORONACIÓN DE PRESASes_ES
dc.subjectDISIPACIÓN DE ENERGÍAes_ES
dc.subjectFRACCIÓN DE VOLUMENes_ES
dc.subjectMALLADOes_ES
dc.subjectSIMULACIÓN NUMÉRICAes_ES
dc.titleAnálisis de parámetros dimensionales en la aireación de chorros rectangulares turbulentos de vertido libre por coronación de presas.es_ES
dc.typemasterThesises_ES
Aparece en las colecciones:Tesis Maestría en Diseño y Simulación (FIM)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CD 13479.pdf1,31 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.