dc.contributor.authorCuello Chungandro, Alexis Daniel-
dc.contributor.editorPérez Yauli, Fabián Ernesto-
dc.date.accessioned2023-11-21T17:53:22Z-
dc.date.available2023-11-21T17:53:22Z-
dc.date.issued2023-09-
dc.identifier.citationCuello Chungandro, A.D. (2023). Guía para el ajuste de las protecciones eléctricas de sistemas DC : guía para el ajuste de la protección diferencial de DC del convertidor y de la protección de circuito abierto de electrodos de un sistema HVDC (High-Voltage Direct Current). 91 páginas. Quito : EPN.es_ES
dc.identifier.otherT-IE 5852 / CD 13758-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/25134-
dc.descriptionEl presente Trabajo de Integración Curricular tiene como finalidad proponer una guía de ajuste de la protección diferencial de DC del convertidor y de la protección de circuito abierto de electrodos en el lado de DC del sistema de transmisión HVDC monopolar de CIGRE, en base a las mejores propuestas de criterios de ajuste identificadas en la literatura técnica disponible. Para la validación de su correcto funcionamiento se ha decidido utilizar al programa de transitorios electromagnéticos más extendido en el mundo ATPDraw. Inicialmente se modela al sistema HVDC monopolar de CIGRE, para posteriormente modelar un evento de falla en bornes del convertidor y la apertura de la línea de electrodos. La protección diferencial de DC del convertidor y la protección de circuito abierto de electrodos sirven para contrarrestar los eventos mencionados. Finalmente se ajustan las dos protecciones sobre el sistema DC base planteado, en función de las mejores propuestas de criterios de ajuste identificadas y se las valida con ayuda de la simulación en el software ATPDraw.es_ES
dc.description.abstractThe purpose of this Curricular Integration Work is to propose an adjustment guide for the DC differential protection of the converter and the open circuit protection of the electrodes on the DC side of the single-pole HVDC transmission system of CIGRE, based on the best proposals of adjustment criteria identified in the available technical literature. For the validation of its correct operation, it has been decided to use the most widespread electromagnetic transient program in the world ATPDraw. Initially, CIGRE's single-pole HVDC system is modeled, to later model a fault event at the converter terminals and the opening of the electrode line. The converter DC differential protection and the electrode open circuit protection serve to counteract the mentioned events. Finally, the two protections are adjusted on the proposed DC base system, according to the best proposals of adjustment criteria identified and validated with the help of the simulation in ATPDraw software.es_ES
dc.language.isospaes_ES
dc.publisherQuito : EPN, 2023.es_ES
dc.rightsopenAccesses_ES
dc.subjectELECTRICIDADes_ES
dc.subjectAJUSTEes_ES
dc.subjectATPDRAWes_ES
dc.subjectCIGREes_ES
dc.subjectCIRCUITO ABIERTOes_ES
dc.subjectCONVERTIDORes_ES
dc.titleGuía para el ajuste de las protecciones eléctricas de sistemas DC : guía para el ajuste de la protección diferencial de DC del convertidor y de la protección de circuito abierto de electrodos de un sistema HVDC (High-Voltage Direct Current).es_ES
dc.typeTrabajo de Integración Curriculares_ES