Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/8568
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorPinto Aguirre, Carlos Alberto-
dc.date.accessioned2014-09-08T21:35:36Z-
dc.date.available2014-09-08T21:35:36Z-
dc.date.issued2014-07-07-
dc.identifier.otherT-IE/3983/CD 5777-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/8568-
dc.description119 hojas : ilustraciones, 29 x 21 cm + CD-ROM 5777es_ES
dc.description.abstractResumen.- En el presente artículo se describen los estudios realizados para el desarrollo de un programa computacional que permite calcular la corriente máxima de conducción en los cables aislados instalados bajo tierra, analizando la conformación de los cables de medio y bajo voltaje se puede determinar la función de cada parte del cable así como su influencia al momento de determinar la corriente máxima a la cual podrán trabajar, pero se podrá observar que la corriente máxima de un conductor no está definida solamente por sus características constructivas sino también por las características de instalación y también ambientales a las cuales el cables será sometido, es por esto que se realizan cálculos para la reducción de la capacidad máxima según factores que ya han sido determinados por normas internacionales pero que dan una respuesta muy conservadora lo que lleva a un aumento de costo al momento de utilizar conductores sobredimensionados, así el programa final permite integrar varios factores ambientales y de instalación lo cual nos permite una gran variabilidad de casos mostrando un cálculo fino y rápido que da como resultado la obtención de la corriente máxima que el cable podrá soportar. Abstract.- This article studies the development of a computer program that calculates the maximum conduction current in insulated cables installed underground, analyzing the conformation of cables and low voltage means you can determine the function descriptions are of the cable and its influence in determining the maximum current which may work, but it will be observed that the maximum current a conductor is not defined only by their structural characteristics but also by the characteristics of installation and environmental which the cable will be submitted, which is why calculations for reducing capacity level factors that have been determined by international standards but they give a very conservative response leading to increased cost when performed using oversized drivers and the final program can integrate various environmental factors and installation which allows us a great variability of cases showing a thin and fast calculation results in obtaining the maximum current that the cable can withstand.es_ES
dc.description.sponsorshipTapia Calvopiña, Luis Elías, directores_ES
dc.language.isospaes_ES
dc.publisherQuito : EPN, 2014.es_ES
dc.rightsopenAccess-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectMatlabes_ES
dc.subjectLenguajes de programaciónes_ES
dc.subjectDistribución de energía eléctricaes_ES
dc.subjectRedes eléctricases_ES
dc.titleCálculo de la ampacidad en redes subterráneas, análisis y simulación usando matlabes_ES
dc.typebachelorThesises_ES
Aparece en las colecciones:Tesis Ingeniería Eléctrica (IE)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CD-5777.pdfTesis completa4,56 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.