Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/10269
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorOrtiz Ávila, Víctor Andrés-
dc.date.accessioned2015-03-19T15:21:02Z-
dc.date.available2015-03-19T15:21:02Z-
dc.date.issued2015-03-09-
dc.identifier.otherT-IE/4063/CD 6133-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/10269-
dc.description130 hojas : ilustraciones, 29 x 21 cm + CD-ROM 6133es_ES
dc.description.abstractResumen .- El presente proyecto se enfoca en determinar la magnitud de las pérdidas técnicas que provoca el Efecto Corona al transmitir energía eléctrica por medio de líneas aéreas de corriente alterna en sistemas de extra alto voltaje. Se ha tomado como caso de estudio la línea de transmisión a 500 kV, comprendida desde la central hidroeléctrica Coca Codo Sinclair, ubicada en la provincia del Napo, hasta la subestación El Inga, en la provincia de Pichincha, del Sistema Nacional de Transmisión Ecuatoriano. Se ha investigado cómo reacciona una línea de transmisión bajo diferentes variables climáticas, atmosféricas, altitudinales, condiciones especiales de temperaturas cercanas al congelamiento y presencia de partículas aéreas como ceniza volcánica. Por esta razón se desarrolló una clasificación por ecosistemas. Se realizó un estudio del comportamiento del campo eléctrico en diferentes haces de conductores para averiguar cuál será el comportamiento de la línea con configuraciones diferentes. También se probó varias configuraciones de torres tipo y se propuso una configuración que minimiza las pérdidas técnicas. Finalmente, se realizó un análisis financiero de las pérdidas, con la intensión de llamar la atención a los organismos gubernamentales para que tomen en cuenta los efectos de este tipo de pérdidas para proyectos en el futuro cercano. Abstract .- This project focuses on determining the extent of technical losses caused by corona effect to transmit electrical energy through AC overhead lines in extra high voltage systems. Is taken as a case study the transmission line 500 kV of the Ecuadorian National Transmission System, ranging from Coca Codo Sinclair hydroelectric plant, located in the Napo province, to the substation El Inga, in the Pichincha province. We investigated how a transmission line reacts under different climatic, atmospheric, altitudinal variables, special conditions of temperatures near freezing point and the presence of airborne particles such as volcanic ash. For this reason an ecosystem classification has been developed. A study of the behavior of the electric field was performed in different wire bundles to find out what will be the behavior of line with different settings. Various configurations of type towers was also tested and settings that minimize technical losses was proposed. Finally, a financial analysis of losses, with the intention of drawing attention to government agencies to take into account the effects of such losses for projects in the near future was made.es_ES
dc.description.sponsorshipCanelos Salazar, Raúl Antonio, directores_ES
dc.language.isospaes_ES
dc.publisherQuito : EPN, 2015.es_ES
dc.rightsopenAccess-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectEnergía eléctricaes_ES
dc.subjectEfecto Coronaes_ES
dc.subjectCentral Hidroeléctrica Coca Codo Sinclaires_ES
dc.titleAnálisis Técnico-Económico de Pérdidas por Efecto Corona en Líneas de Transmisión de 500 kV del Sistema Nacional de Transmisión Ecuatoriano en el tramo Coca-Codo El Ingaes_ES
dc.typebachelorThesises_ES
Aparece en las colecciones:Tesis Ingeniería Eléctrica (IE)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CD-6133.pdf35,08 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.