Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/10559
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorCulqui Correa, Nora Araceli-
dc.date.accessioned2015-05-18T18:12:33Z-
dc.date.available2015-05-18T18:12:33Z-
dc.date.issued2015-05-12-
dc.identifier.otherT-IQ/0946/CD 6246-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/10559-
dc.description184 hojas : ilustraciones, 29 x 21 cm + CD-ROM 6246es_ES
dc.description.abstractResumen .- En este proyecto se diseña e implementa una planta de 20 L/día de capacidad, para el tratamiento de dos tipos de efluentes que se generan en los laboratorios del DEMEX. La caracterización de los efluentes cianurados reveló la presencia masiva de Cu 55 mg/L y Ag 23 mg/L; así como DQO 14 522 mg/L y 12 430 unidades de color para efluentes orgánicos. Para purificar estos efluentes se emplearon los procesos de sedimentación, filtración, electrocoagulación y fitorremediación, hasta disminuir la concentración de los contaminantes a valores inferiores a los establecidos en la normativa ambiental vigente. Se definieron las mejores condiciones de operación en cada etapa experimental y estos resultados se utilizaron para el dimensionamiento de: un sedimentador, un reactor electrolítico, un filtro a presión y un sistema de humedales artificiales de flujo sub superficial vertical. Estos equipos fueron instalados en el DEMEX y, al evaluar su funcionamiento se obtuvieron los siguientes porcentajes de remoción de contaminantes: 99 % Cu (0,5 mg/L), 99,9 % Ag (0,01 mg/L), 98,2 % DQO (261 mg/L) y 99,6 % color (48 unidades de color). Las concentraciones finales de los contaminantes cumplen los límites normados, lo cual demuestra la efectividad de la planta piloto implementada. Abstract .- This project shows the design and implement of a plant of 20 L capacity to treat two types of effluents generated in the DEMEX’s laboratories. The characterization of the cyanide effluent showed the massive presence of Cu 55 mg/L and Ag 23mg/L. On the other hand COD 14 522 mg/L and a dark brown hue corresponding to 12 430 color units for organic effluents. To purify these effluents processes of sedimentation, filtration, electrocoagulation and phytoremediation were employed to reduce the concentration of pollutants below the established values current environmental regulations. The best operating conditions in each experimental stage were defined and these results were used for sizing: a settler, an electrolytic reactor, a pressure filter and a system of artificial wetlands vertical subsurface flow. The equipment were installed in the DEMEX and in the performance evaluation the following percentages of pollutant removal were obtained: 99% Cu (0,5 mg / L); Ag 99,9% (0,01 mg / L); 98,2% COD (261 mg / L) and 99,6% color (48 color units). Final concentrations of pollutants meet regulatory limits. It demonstrates the effectiveness of the pilot plant implemented.es_ES
dc.description.sponsorshipGuevara Caiquetán, Alicia del Carmen, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2015.es_ES
dc.rightsopenAccess-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectDiseño de plantases_ES
dc.subjectBalance de masaes_ES
dc.subjectBalance de energíaes_ES
dc.titleDiseño e implementación de una planta piloto para el tratamiento de efluentes líquidos generados en los laboratorios del DEMEXes_ES
dc.typebachelorThesises_ES
Aparece en las colecciones:Tesis Ing. Química (IQUIM)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CD-6246.pdf3,66 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.