Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/11064
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorQuishpe Otacoma, Carlos Paúl-
dc.date.accessioned2015-07-16T16:55:12Z-
dc.date.available2015-07-16T16:55:12Z-
dc.date.issued2015-07-14-
dc.identifier.citationQuishpe Otacoma, C. P. (2015). Estudio de las conexiones para muros estructurales mixtos acero-concreto. Quito : EPN.es_ES
dc.identifier.otherT-MVE/0348/CD 6377-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/11064-
dc.description153 hojas : ilustraciones, 29 x 21 cm + CD-ROM 6377es_ES
dc.description.abstractResumen .- La presente investigación pretende estudiar el comportamiento de los muros de corte de acero-concreto. Se diseña los ensayos para dos muros de acero-concreto, ambos tienen igual diagrama de flexo-compresión, sin embargo, se diferencian en la forma constructiva, el primero tiene el refuerzo transversal anclado en el hormigón de las columnas y conectores soldados a los elementos de acero. En el segundo se suelda el refuerzo transversal a las columnas y se duplica la cantidad de conectores. En sitios estratégicos se colocan Strain gauges para obtener una gráfica carga vs deformación unitaria del acero, además se coloca LVDT para obtener la curva de histéresis del muro a una altura de 4.2m y de 2.1m. Finalmente, se ensaya y los datos obtenidos son estudiados para analizar el comportamiento de los muros de corte de acero-concreto. Abstract .- This research aims to study the behavior of steel-concrete shear walls. Test for two steel-concrete shear walls is designed, both have equal flexural-compression diagram, however, these are constructed differently, the first wall have transverse reinforcement anchored in the concrete columns and the studs are welded to the steel elements. In the second wall, transverse reinforcement is welded to the columns and the amount of studs is doubled. Strain gauges are strategically placed in order to obtain load-deformation graph, LVDT are placed to get the hysteresis curve of the wall at a height of 2.1m and 4.2m. Finally, they are tested and the data obtained are study to analyze the behavior of steel-concrete shear walls.es_ES
dc.description.sponsorshipPlacencia Andrade, Patricio Honorato, directores_ES
dc.language.isospaes_ES
dc.rightsopenAccess-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectEstructuras (Construcción)es_ES
dc.subjectHormigoneses_ES
dc.subjectAceroes_ES
dc.titleEstudio de las conexiones para muros estructurales mixtos acero-concretoes_ES
dc.typemasterThesises_ES
Aparece en las colecciones:Tesis Maestría en Estructuras (FICA)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CD-6377.pdf44,19 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.