Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/15632
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorTapia Hinojosa, Mónica Paulina-
dc.date.accessioned2016-06-08T17:38:51Z-
dc.date.available2016-06-08T17:38:51Z-
dc.date.issued2016-01-08-
dc.identifier.citationTapia Hinojosa, M. P. (2016). Evaluación de la eficiencia de la remoción de hidrocarburos totales de lodos petrolizados empleando un procedimiento de oxidación química. 97 hojas. Quito : EPN.es_ES
dc.identifier.otherT-PIA/0082/CD 7071-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/15632-
dc.descriptionLa presente investigación tuvo como objetivo analizar la eficiencia de la remoción de TPHs presentes en lodos de fondo de tanques provenientes de actividades petroleras, mediante el uso del reactivo de Fenton. Durante la fase experimental se ensayaron tres diferentes concentraciones de reactivo Fenton (H2O2-Fe): 10% (T1), 20% (T2) y 30% (T3) (v/v) de Peróxido de Hidrógeno, manteniendo la misma concentración de hierro. Los tratamientos consistieron en realizar tres aplicaciones consecutivas de reactivo Fenton a una misma masa de muestra; además los tratamientos se realizaron por triplicado, dando 27 ensayos en total. Tanto al inicio de cada tratamiento como luego de cada aplicación se determinó la concentración de TPHs acorde al método TNRCC 1005. Los resultados obtenidos mostraron que los tratamientos lograron remover el 44,39 %, 42,40 % y 44,25 % de TPHs para los tratamientos T1, T2 y T3, respectivamente; siendo el tratamiento T1 el más eficiente con el 44,39%. Del análisis cromatográfico se determinó que la mayor eficiencia de remoción se dió en los hidrocarburos presentes en menor concentración. Siendo entre el C6 al C11 y entre el C21 al C30, sin embargo los hidrocarburos intermedios tuvieron mejor remoción al aplicar el reactivo Fenton al 30%.es_ES
dc.description.abstractThe present work aimed to evaluate the removal treatment procedure of TPHs concentrated in tank bottom sludge from petroleum extraction activities through the application of Fenton’s reagent. It was tested three different Fenton´s reagent concentrations: at 10% (T1), 20% (T2) y 30% (T3) (v/v) of Hydrogen peroxide (H2O2-Fe) and always keeping the same iron concentration ratio. The tests were done applying three consecutives Fenton´s reagent treatments in the same sample, given a total of 27 experiments. The analytical measurements were approached using TNRCC1005 method. The results indicated that the three procedures achieved 44,39%, 42,40% and 44,25% TPH removal in the corresponding T1, T2, and T3 treatments. Therefore, it was seen that the better results were obtained in T1 using Fenton´s reagent at 10% (v/v). The chromatographic analysis showed that the better removal efficiency was obtained in hydrocarbons with lower initial concentration, i.e. C6 to C11 and C21 to C30. For intermediate samples, i.e. C12 to C20, the best results were obtained applying Fenton´s reagent at 30%es_ES
dc.description.sponsorshipBalarezo Aguilar, Ana Lucía, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2016.es_ES
dc.rightsopenAccess-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectSueloses_ES
dc.subjectOxidación químicaes_ES
dc.subjectQuímicaes_ES
dc.titleEvaluación de la eficiencia de la remoción de hidrocarburos totales de lodos petrolizados empleando un procedimiento de oxidación químicaes_ES
dc.typemasterThesises_ES
Aparece en las colecciones:Tesis Maestría en Ingeniería Ambiental (FICA)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CD-7071.pdf5,27 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.