dc.contributor.authorHeredia Calvopiña, Néstor Xavier-
dc.date.accessioned2016-11-30T20:07:30Z-
dc.date.available2016-11-30T20:07:30Z-
dc.date.issued2016-10-24-
dc.identifier.citationHeredia Calvopiña, N. X. (2016). Diseño de un sistema recuperador de fibra celulósica a partir de corrientes residuales provenientes de una planta recicladora de papel. 87 hojas. Quito : EPN.es_ES
dc.identifier.otherT-IQ/1045/CD 7478-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/16899-
dc.descriptionEl presente proyecto tiene como objetivo diseñar un sistema recuperador de fibra celulósica a partir de corrientes residuales provenientes de una planta recicladora de papel. Se identificaron puntos de perdida de fibra celulósica en corrientes provenientes del área de espesado de la planta recicladora de papel, el agua residual contiene en promedio 0,99% en peso de fibras recuperables y 26,17% de material inorgánico conformado principalmente por tintas. El porcentaje de fibra celulósica presente en el efluente con tamaño mayor a 100 mesh o 150 µm, idóneo para la fabricación de papel tisú es de 35,78%. El sistema de recuperación de fibra fue dimensionado con el objetivo de tratar un caudal promedio de 77,56 m3/h y está conformado por un tanque agitado de dilución, una criba estática inclinada y un tanque agitado de homogenización. Se utilizó el método de paso de Matthews para el diseño del filtro tipo malla con un 70 % de retención y conceptos de mecánica de fluidos para el diseño de agitadores. Se determinó mediante los balances de masa que la cantidad de celulosa recuperada es de 4,65 t/día representando un valor de 880 041,10 USD/año.es_ES
dc.description.abstractThe present project aims to design a recuperative system of cellulosic fiber from waste streams from a paper recycling plant. Cellulosic fiber loss points were identified in streams from the thickening area of the paper recycling plant, the waste water containing on average 0.99% by weight of recoverable fibers and 26.17% of inorganic material mainly made up of inks. The percentage of cellulosic fiber present in the effluent with a size greater than 100 mesh or 150 μm, suitable for the manufacture of tissue paper is 35.78%. The fiber recovery system was designed to treat an average flow rate of 77.56 m3 / h and consists of a stirred dilution tank, a sloped static screen and a stirred homogenization tank. The Matthews step method was used for mesh filter design with 70% retention and fluid mechanics concepts for the design of agitators. It was determined by mass balances that the amount of recovered cellulose is 4.65 t / day representing a value of 880 041.10 USD / year.es_ES
dc.description.sponsorshipSalvador Quiñones, Marcelo Fernando, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2016.es_ES
dc.rightsopenAccess-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectOPERACIONES UNITARIASes_ES
dc.subjectBALANCE DE MASAes_ES
dc.subjectBALANCE DE ENERGÍAes_ES
dc.titleDiseño de un sistema recuperador de fibra celulósica a partir de corrientes residuales provenientes de una planta recicladora de papeles_ES
dc.typebachelorThesises_ES
Aparece en las colecciones:Tesis Ing. Química (IQUIM)

Ficheros en este ítem: