Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/17040
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorBermeo Fárez, Carla Jhomayra-
dc.contributor.authorSánchez Oñate, Diego Mauricio-
dc.date.accessioned2017-02-08T20:22:43Z-
dc.date.available2017-02-08T20:22:43Z-
dc.date.issued2017-01-17-
dc.identifier.citationBermeo Fárez, C. J., & Sánchez Oñate, D. M. (2017). Comportamiento de la conexión Losa-Columna en pórticos con vigas banda en nudos interiores. 144 hojas. Quito : EPN.es_ES
dc.identifier.otherT-MVE/0505/CD 7622-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/17040-
dc.descriptionLas losas con vigas banda en estructuras de hormigón armado son ampliamente usadas en el Ecuador debido a su bajo costo, facilidad de construcción y aspecto arquitectónico. Las losas planas han demostrado que tienes un buen comportamiento ante cargas verticales, sin embargo, se han reportado numerosos colapsos estructurales en edificaciones con este sistema constructivo durante eventos sísmicos. El colapso producido en este tipo de estructuras es preocupante pues las fallas se han producido debido a punzonamiento de las losas alrededor de las columnas. Este tipo de falla ocurre de forma repentina y por lo tanto se debe evitarla. En este estudio, se construyeron dos modelos de prueba a escala real. Se construyeron dos nudos interiores de un edificio con losas planas y fueron ensayadas ante una combinación de cargas verticales y laterales para observar el comportamiento de la conexión losa columna. La carga horizontal fue aplicada de forma cíclica y se colocó una sobre carga en la losa para simular la carga vertical de una edificación en servicio normal. Estos experimentos mostraron que el tipo de falla que se produce en estructuras de hormigón con losas planas es frágil. En ambos modelos la falla fue debido a corte en dos direcciones o punzonamiento antes de que se produzca falla por flexión.es_ES
dc.description.abstractFlat slabs are widely used in reinforced concrete construction in Ecuador because of their low cost, short construction times and architectural appearance. Flat slabs have a good performance for vertical loads, however, several structural collapses have been reported during seismic events. These failures are commonly referred to as “punching shear” failures as the column appears to punch through the slab as the latter drops away from the failure surface around the column. These failures appear suddenly; therefore it is necessary to prevent them. In this experiment, two full scale specimens were constructed. Two flat slab building interior connection were tested under gravity and seismic load to evaluate the slab column connection performance. The results showed that the failure of this structural system is fragile. In both specimens the failure due to the punching shear occurred before flexural yielding had been developed.es_ES
dc.description.sponsorshipPlacencia Andrade, Patricio Honorato, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2017.es_ES
dc.rightsopenAccess-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectESTRUCTURAS (CONSTRUCCION)es_ES
dc.subjectHORMIGONESes_ES
dc.subjectESTRUCTURACION SISMICAes_ES
dc.titleComportamiento de la conexión Losa-Columna en pórticos con vigas banda en nudos interioreses_ES
dc.typemasterThesises_ES
Aparece en las colecciones:Tesis Maestría en Estructuras (FICA)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CD-7622.pdf9,86 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.