Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/17493
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorPillajo Quijia, Hugo Hermel-
dc.date.accessioned2017-07-17T17:36:49Z-
dc.date.available2017-07-17T17:36:49Z-
dc.date.issued2017-07-17-
dc.identifier.citationPillajo Quijia, H. H. (2017). Evaluación de la conexión precalificada: viga de sección reducida-columna cajón relleno, para pórticos de momento a base de planchas de acero A36 soldadas. 209 hojas. Quito : EPN.es_ES
dc.identifier.otherT-MVE/0566/CD 7994-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/17493-
dc.descriptionEl presente proyecto tiene como objetivo evaluar el comportamiento de la conexión precalificada viga-columna para un edificio en acero y determinar si cumple con requerimientos de ductilidad y capacidad de disipación de energía, considerando que nuestro país se encuentra en una alta zona sísmica. El prediseño de elementos principales vigas y columnas, es realizado en base a los planos arquitectónicos del edificio Jade, posterior se emplea el software ETABS y los requerimientos de la Norma Ecuatoriana de la Construcción NEC para modelar y realizar el Análisis Estático. Se procede con el análisis por elementos finitos de la conexión exterior viga-columna empleando el software SOLIDWORKS, con esto se predice su comportamiento y se observan zonas críticas de la conexión. En el taller, se fabrica la viga y la columna a escala real. Se realiza el fundido del hormigón de la columna. La soldadura de la conexión se ejecuta emulando posiciones y ambientes reales en obra, todo esto según requerimientos de los Códigos AISC 341-16, AISC 358-16, FEMA 350, AWS D1.1-15. El ensayo experimental se desarrolla en el Centro de Investigación de la Vivienda CIV-EPN. Posterior se evalúa la conexión exterior con criterios de Calificación del Código AISC 341-16.es_ES
dc.description.abstractThe present project aims to evaluate the behavior of the beam-column prequalified connection for steel building and to determine if it meets ductility requirements and energy dissipation capacity, considering that our country is in a high seismic zone. The pre-design of main elements beams and columns, is made based on the architectural plans of the Jade building, later the ETABS software is used and the requirements of the Ecuadorian Construction Standard NEC to model and perform the Static Analysis. Finite element analysis of the beam-column outer connection is carried out using the SOLIDWORKS software, which predicts its behavior and observes critical areas of the connection. In the workshop, the beam and column is fabricated in real scale. The casting of the concrete of the column is made. The welding of the connection is executed by emulating actual positions and environments on site, all according to the requirements of AISC Codes 341-16, AISC 358-16, FEMA 350, AWS D1.1-15. The experimental trial is developed at the CIV-EPN Housing Research Center following the requirements of AISC 341-16 and FEMA 350. Subsequently the external connection is evaluated according to the criteria of AISC Code 341-16.es_ES
dc.description.sponsorshipVintimilla Jaramillo, Jorge Ricardo, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2017.es_ES
dc.rightsopenAccesses_ES
dc.subjectESTRUCTURAS (CONSTRUCCION)es_ES
dc.subjectINGENIERÍA SISMORRESISTENTEes_ES
dc.subjectELEMENTOS FINITOSes_ES
dc.titleEvaluación de la conexión precalificada: viga de sección reducida-columna cajón relleno, para pórticos de momento a base de planchas de acero A36 soldadases_ES
dc.typemasterThesises_ES
Aparece en las colecciones:Tesis Maestría en Estructuras (FICA)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CD-7994.pdf24,05 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.