Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/18759
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorMolineros Salgado, Carlos Daniel-
dc.date.accessioned2017-09-04T14:10:12Z-
dc.date.available2017-09-04T14:10:12Z-
dc.date.issued2017-09-04-
dc.identifier.citationMolineros Salgado, C. D. (2017). Estudio de la relación entre la distribución espacial de la actividad de iodo 131 y la distribución de intensidades en la imagen SPECT/CT correspondiente. 80 hojas. Quito : EPN.es_ES
dc.identifier.otherT-MVE/0596/CD 8147-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/18759-
dc.descriptionEn este trabajo, se simularon mediante métodos Monte Carlo todos los procesos relacionados a la formación de la imagen de un fan toma NEMA/IEC con un equipo SPECT/CT Siemens Symbian Intevo Excel. En base a estas simulaciones se desarrolló un método que permite determinar la distribución tridimensional de la actividad dentro del fan toma partiendo de sus imágenes SPECT/CT. En primer lugar se simulo la emisión de fotones desde el fan toma voxelizado cargado con actividades conocidas de 131I, su detección en los cristales de las gama cámaras y la producción de las imágenes que formaran las proyecciones. A partir de las proyecciones obtenidas, se realizó todo el proceso de corrección, reconstrucción y fusión para producir los cortes tomográficos propios de un estudio SPECT/CT. El método planteado en base a las simulaciones se validó mediante un montaje experimental equivalente al sistema simulado. En el experimento cada inserto del fan toma se cargó con 131I de modo que las actividades eran conocidas en cada adquisición de imagen. De la comparación realizada entre la simulación y el experimento se determinó que el método de estimación desarrollado es adecuado para actividades mayores a 2mCi contenidas en volúmenes mayores al volumen de resolución del equipo (1800mm3), en estas condiciones error de estimación es menor al 10 %.es_ES
dc.description.abstractIn this work, all the processes related to the formation of the image of a NEMA/IEC phantom with a Siemens Simbia Intevo Excel SPECT/CT scanner were simulated using Monte Carlo simulations. Based on these simulations a method that allows the determination of the tridimensional distribution of the activity inside the phantom from on its SPECT/CT images was developed. The first simulated process was the emission of photons from the voxelized phantom filled with known activites of iodine-131, the detection of this photons in the gamma camera’s detector crystals, and the image production. The projections obtained were corrected, reconstructed and fused to the tomographic images. The method developed was validated with an experimental setup equivalent to the simulated one. In the experiment each container in the phantom was loaded with 131I so that the activities were known for each image acquisition. From the comparison between the simulation and the experiment, it was concluded that the method developed is suitable for activities lower than 2mCi contained in volumes greater than the machine’s resolution volume (1800mm3), in these conditions the method has a estimation error lower that 10 %.es_ES
dc.description.sponsorshipBayas Rea, Marco Vinicio, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2017.es_ES
dc.rightsopenAccesses_ES
dc.subjectMEDICINA NUCLEARes_ES
dc.subjectMETODOS MONTECARLOes_ES
dc.subjectFISICA MEDICAes_ES
dc.titleEstudio de la relación entre la distribución espacial de la actividad de iodo 131 y la distribución de intensidades en la imagen SPECT/CT correspondientees_ES
dc.typemasterThesises_ES
Aparece en las colecciones:Tesis Maestría en Física Médica (FC)