Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/18878
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorChiguano Velasco, Alvaro Napoleón-
dc.date.accessioned2017-10-30T16:03:34Z-
dc.date.available2017-10-30T16:03:34Z-
dc.date.issued2017-10-30-
dc.identifier.citationChiguano Velasco, A. N. (2017). Reducción de pérdidas y de la duración de las interrupciones en alimentadores primarios mediante su reconfiguración óptima. Estudio de caso de la Empresa Eléctrica Riobamba. 1296 hojas. Quito : EPN.es_ES
dc.identifier.otherT-IE/4539/CD 8271-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/18878-
dc.descriptionLa normativa vigente del sector eléctrico busca regular la calidad y confiabilidad del servicio prestado por las empresas distribuidoras a los usuarios. De ahí que, para las distribuidoras se vuelve fundamental conocer en detalle las condiciones de operación del sistema en estado normal y ante contingencias. Dentro de esta perspectiva, contar con un control eficiente de niveles de pérdidas, así como reducir la duración de las interrupciones, son acciones que incrementan la eficiencia del suministro de energía eléctrica. En el presente trabajo, mediante una evaluación y análisis comparativo de las metodologías Shirmohammadi y Goswami para reducción de pérdidas mediante reconfiguración, se propone un método que combina las mejores características de estas, la cual incrementa la eficacia y la calidad de los resultados encontrados, además, se propone un método de resolución al problema de la restauración del servicio con mínima cantidad de operaciones, el cual corresponde a un resultado derivado de la solución al problema de reducción de pérdidas, en el que se encamina a tomar prioridad en evitar cambios en los estados iniciales de los interruptores, ya sean normalmente abiertos (NA) o normalmente cerrados (NC).es_ES
dc.description.abstractThe actual regulation of the electricity sector seeks to regulate the quality and reliability of the service provided by the distribution companies to the users. Hence, for the distribution companies it becomes fundamental to know in detail the operating conditions of the system in normal state and during contingencies. In this perspective, to have an efficient control of loss levels, as well as to reduce the duration of interruptions, is necesary to determine actions that increase the efficiency of the electric power supply. In the present work, by means of an evaluation and comparative analysis of the Shirmohammadi and Goswami methodologies to reduce loss through reconfiguration, a method is proposed which combines the best characteristics of these, this method increases the efficiency and the quality of the results found. In addition , a resolution method is proposed for the problema of the restoration of the service with a minimum number of operations, which corresponds to a result derived from the solution to the problem of reduction of losses, in which it is directed to take priority in avoiding changes in the initial states of the switches, either normally open (NO) or normally closed (NC).es_ES
dc.description.sponsorshipVásquez Miranda, Paúl Fabricio, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2017.es_ES
dc.rightsopenAccesses_ES
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectSISTEMAS DE DISTRIBUCIÓNes_ES
dc.subjectCALIDAD DE ENERGÍAes_ES
dc.subjectMETODOLOGIA SHIRMOHAMMADIes_ES
dc.subjectMETODOLOGIA GOSWAMIes_ES
dc.titleReducción de pérdidas y de la duración de las interrupciones en alimentadores primarios mediante su reconfiguración óptima. Estudio de caso de la Empresa Eléctrica Riobambaes_ES
dc.typebachelorThesises_ES
Aparece en las colecciones:Tesis Ingeniería Eléctrica (IE)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CD-8271.pdf3,53 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.