dc.contributor.authorRamos Chávez, María Carolina-
dc.contributor.authorTupiza Tupiza, Sara Raquel-
dc.date.accessioned2018-06-05T19:29:39Z-
dc.date.available2018-06-05T19:29:39Z-
dc.date.issued2018-06-05-
dc.identifier.citationRamos Chávez, M. C., & Tupiza Tupiza, S. R. (2018). Diseño y construcción de un modelo a escala de la línea de transmisión de 500 kV Coca Codo Sinclair - El Inga para el Laboratorio de Sistemas Eléctricos de Potencia. 177 hojas. Quito : EPN.es_ES
dc.identifier.otherT-IE/4673/CD 8850-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/19454-
dc.descriptionSe realiza el diseño y construcción de un modelo a escala de la línea de transmisión de 500 kV Coca Codo Sinclair – El Inga, con el fin de efectuar estudios experimentales en estado estable y transitorio. Se construyen dos módulos considerando para cada uno la mitad de la longitud de la línea de transmisión real. En base a la matriz de impedancias y admitancias reducidas, resultantes del modelamiento en el software Power Factory de DigSILENT, se realiza el diseño de los modelos electromagnéticos y electrostáticos equivalentes para cada uno de los módulos. Las especificaciones de los elementos inductivos y capacitivos se obtienen mediante los valores nominales de voltaje y potencia de la línea de 500 kV y se los relaciona con los valores nominales del Laboratorio de Sistemas Eléctricos de Potencia mediante una conversión en valores en por unidad que reflejan de manera exacta los parámetros reales de la línea de transmisión. El modelo electromagnético está representado por bobinas de núcleo de aire y bobinas de núcleo de hierro, mientras que el modelo electrostático está representado por capacitores entre fases y fase a tierra. Se efectúan mediciones de parámetros eléctricos, medición del efecto Ferranti, fallas de cortocircuitos y flujos de potencia.es_ES
dc.description.abstractThe design and construction of a scale model of the Coca Codo Sinclair - El Inga 500 kV transmission line is implemented, to carry out experimental studies in stable and transient states. Modules are built considering half of the real transmission line length for each one. Based on the impedances and admittances reduced matrices, obtained through modeling in DigSILENT Power Factory software. The design of the electromagnetic and electrostatic equivalent model for each of the modules is realized. The specifications of the inductive and capacitive elements are achieved by means of the nominal values of voltage and power of the 500 kV system and are related to the nominal values of the Power Electrical Systems Laboratory through a conversion into per unit values that reflect in an exact transmission line actual parameters. The electromagnetic model is represented by coils of air core and iron core. The electrostatic model is represented by capacitors between phases and phase to ground. Measurements of electrical parameters, Ferranti effect, short-circuit and power flow are carried out.es_ES
dc.description.sponsorshipJátiva Ibarra, Jesús Amado, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2018.es_ES
dc.rightsopenAccesses_ES
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectSISTEMAS ELÉCTRICOS DE POTENCIAes_ES
dc.subjectLÍNEAS DE TRANSMISIÓNes_ES
dc.subjectAPLICACIONES DE COMPUTADORes_ES
dc.titleDiseño y construcción de un modelo a escala de la línea de transmisión de 500 kV Coca Codo Sinclair - El Inga para el Laboratorio de Sistemas Eléctricos de Potenciaes_ES