Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/19541
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorSerrano Aguirre, Saúl-
dc.date.accessioned2018-07-12T20:50:24Z-
dc.date.available2018-07-12T20:50:24Z-
dc.date.issued2018-07-12-
dc.identifier.citationSerrano Aguirre, S. (2018). Estimación rápida de la dosis absorbida por los órganos durante una tomografía con el escáner Discovery ST8. 90 hojas. Quito : EPN.es_ES
dc.identifier.otherT-FCF/0169/CD 8939-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/19541-
dc.descriptionEn este trabajo, se estimó la dosis media que recibirían los órganos de un paciente tipo al ser irradiado con el tomógrafo «Discovery ST8» del Hospital SOLCA – Matriz. Primero, se analizó la irradiación asociada a los protocolos utilizados para la adquisición de imágenes. En la región de la cabeza se entregan dosis entre 12 y 25mGy; los lentes de los ojos reciben la menor dosis, mientras que la tiroides recibe la mayor. En la región del tórax, las dosis recibidas varían entre 5.2 y 9.6mGy, en esta región los senos reciben la menor dosis mientras que los pulmones reciben la mayor. En la región de la pelvis, el colon recibe la menor dosis entre 4.6 y 8.1mGy, además, en el caso de los hombres, los testículos reciben la mayor dosis entre 14.0 y 8.0mGy, mientras que, en las mujeres, la vejiga urinaria es la que recibe la mayor dosis entre 13 y 7.2mGy. Segundo, al irradiar todo el cuerpo las dosis van entre 4.7mGy para la piel y 29mGy para la tiroides, además, en todas las regiones, las mismas condiciones de irradiación de un protocolo entregan mayor dosis que las otras.es_ES
dc.description.abstractIn this work, estimated the average dose that the organs of a typical patient would receive when irradiated with the "Discovery ST8" tomograph of the SOLCA - Matriz Hospital. First, the irradiation associated with the protocols used for the acquisition of images was analyzed. In the region of the head doses between 12 and 25mGy are delivered; the lenses of the eyes receive the lowest dose, while the thyroid receives the largest. In the region of the thorax, the received doses vary between 5.2 and 9.6mGy, in this region the breasts receive the lowest dose while the lungs receive the highest. In the region of the pelvis, the colon receives the lowest dose between 4.6 and 8.1mGy, in addition, in the case of men, the testicles receive the highest dose between 14.0 and 8.0mGy, while, in women, the urinary bladder is the one that receives the highest dose between 13 and 7.2mGy. Second, when irradiating the whole body, the doses are between 4.7mGy for the skin and 29mGy for the thyroid, in addition, in all regions, the same irradiation conditions of a protocol deliver higher doses than the others.es_ES
dc.description.sponsorshipBayas Rea, Marco Vinicio, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2018.es_ES
dc.rightsopenAccesses_ES
dc.subjectDOSIMETRÍAes_ES
dc.subjectFÍSICA MEDICAes_ES
dc.titleEstimación rápida de la dosis absorbida por los órganos durante una tomografía con el escáner Discovery ST8es_ES
dc.typebachelorThesises_ES
Aparece en las colecciones:Tesis Física (FISICA)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CD-8939.pdf2,85 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.