Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/19933
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorCabezas Félix, Daniel Ricardo-
dc.date.accessioned2019-02-06T19:04:00Z-
dc.date.available2019-02-06T19:04:00Z-
dc.date.issued2019-01-16-
dc.identifier.citationCabezas Félix, D. R.(2019). Diseño y análisis energético-psicrométrico de un nuevo sistema de ventilación y acondicionamiento de aire del área de microbiología y zona estéril de una empresa farmacéutica en la ciudad de Quito, Distrito Metropolitano. 208 hojas. Quito : EPN.es_ES
dc.identifier.otherT-IM/2013/CD 9386-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/19933-
dc.descriptionEste trabajo expone el diseño y análisis energético-psicrométrico de un nuevo sistema de ventilación y acondicionamiento de aire para las áreas de zona de microbiología y zona estéril de una empresa farmacéutica en la ciudad de Quito, Distrito Metropolitano. El proceso de diseño se lleva a cabo siguiendo lineamientos óptimos expuestos en diversas fuentes bibliográficas y con la ayuda del programa Revit versión 2019 de Autodesk, con el cual se establece una comparación del cálculo de cargas térmicas y caudales de aire de ventilación requeridos para el local. Los parámetros de diseño más importantes son: análisis de cargas de enfriamiento locales, renovaciones de aire por hora requeridas de acuerdo a la norma NOM-059-SSA1-2015 para salas blancas (20RPH), calidad y conteo de partículas por metro cúbico de aire en los locales, condiciones físicas y operativas del emplazamiento y optimización de costo inicial de ductería y equipos. Se expone el modelo 3D y los planos de los sistemas de suministro y extracción del sistema HVAC, detallando el sistema de ductería, accesorios y equipos utilizados. De igual manera se muestra el costo de materia prima y equipos requeridos necesario en una futura implementación del sistema HVAC en un laboratorio farmacéutico.es_ES
dc.description.abstractThis work exposes the design and energetic-psychrometric analysis of a new ventilation and air conditioning system for the areas of microbiology and sterile zone of a pharmaceutical company in the city of Quito, Metropolitan District. The design process is carried out following optimal guidelines exposed in various bibliographic sources and with the help of the Revit program version 2019 of Autodesk, with which a comparison of the calculation of thermal loads and ventilation airflows required for the areas is established. The most important design parameters are: analysis of local cooling loads, hourly air renewals required according to the standard NOM-059-SSA1-2015 for clean rooms, quality and particle count per cubic meter of air in the area of study, physical and operational conditions of the site and optimization of initial cost of ducts and equipment. The 3D model and the drawings of the supply and extraction systems of the HVAC system are exposed, detailing the duct system, accessories and equipment used. Likewise, the cost of raw material and required equipment needed in a future implementation of the HVAC system in a pharmaceutical laboratory is shown.es_ES
dc.description.sponsorshipLópez Villada, Jesús, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2019.es_ES
dc.rightsopenAccesses_ES
dc.subjectVENTILACIÓNes_ES
dc.subjectSUMINISTROes_ES
dc.titleDiseño y análisis energético-psicrométrico de un nuevo sistema de ventilación y acondicionamiento de aire del área de microbiología y zona estéril de una empresa farmacéutica en la ciudad de Quito, Distrito Metropolitano.es_ES
dc.typebachelorThesises_ES
Aparece en las colecciones:Tesis Mecánica (IM)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CD-9386.pdf5,14 MBAdobe PDFVisualizar/Abrir