Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/20236
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorRamírez Ramírez, Cristina Estefanía-
dc.date.accessioned2019-05-30T14:47:34Z-
dc.date.available2019-05-30T14:47:34Z-
dc.date.issued2019-05-21-
dc.identifier.citationRamírez Ramírez, C. E. (2019). Cálculo de la dosis absorbida en pulmones durante una tomografía helicoidal con el tomógrafo “Brilliance Big Bore”, mediante simulaciones Monte Carlo. 96 hojas. Quito : EPN.es_ES
dc.identifier.otherT-FCF/0178/CD 9700-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/20236-
dc.descriptionEn este trabajo se analizaron las características de las dosis absorbidas en los pulmones de una paciente anónima sometida a una TC helicoidal de tórax con el escáner Brilliance Big Bore (BBB) del Hospital Oncológico SOLCA-Quito. El estudio utilizó la plataforma GATE para realizar simulaciones Monte Carlo del proceso de irradiación del tórax de la paciente, el cual incluye los parámetros del protocolo de irradiación: 120 kVp, 200 mAs, NT=24 mm y pitch=0.69. La irradiación del fantoma voxelizado, correspondiente al tórax de la paciente, se simuló para tiempos entre 0.3 y 12 s, manteniendo la rodaja central en la mitad de la porción irradiada. La irradiación de 12 s corresponde a la irradiación del fantoma completo, en este caso, la dosis global encontrada en los pulmones fue 31.19 ± 0.01 mGy; esta dosis difiere en menos del 2% de las dosis D50. Las dosis obtenidas para las irradiaciones parciales se utilizaron para calcular factores de escalamiento. Estos permiten calcular la dosis asociada a la irradiación completa en base a irradiaciones parciales para cualquier fantoma voxelizado construido a partir de la imagen tomográfica obtenida en el tomógrafo BBB.es_ES
dc.description.abstractIn this work, the characteristics of the absorbed doses in the lungs of an anonymous patient subjected to a thoracic helical CT, with 120 kVp, 200 mAs, NT=24 mm and pitch=0.69, was analyzed. The scan was obtained with the Brilliance Big Bore scanner (BBB) from the SOLCA-Quito Oncology Hospital. The study used GATE to perform Monte Carlo simulations of the irradiation process of the patient's chest, using the parameters of the irradiation protocol. The irradiation of the voxelized phantom, corresponding to the patient´s thorax, was simulated for periods between 0.3 and 12 s, keeping the central slice in the middle of the irradiated portion. The 12-seconds irradiation corresponds to the irradiation of the whole phantom, in this case, the overall dose evaluated in lungs was 31.19 ± 0.01 mGy; this dose differ by less than 2% of the D50 doses. The doses obtained for the partial irradiations were used to calculate scaling factors. The scaling factor allow to calculate the dose associated with the complete irradiation based on a partial irradiation for any voxelized phantom constructed from the tomographic image obtained in the BBB tomograph.es_ES
dc.description.sponsorshipBayas Rea, Marco Vinicio, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2019.es_ES
dc.rightsopenAccesses_ES
dc.subjectFÍSICA MÉDICAes_ES
dc.subjectDOSIMETRÍAes_ES
dc.subjectSIMULACIÓNes_ES
dc.titleCálculo de la dosis absorbida en pulmones durante una tomografía helicoidal con el tomógrafo “Brilliance Big Bore”, mediante simulaciones Monte Carloes_ES
dc.typebachelorThesises_ES
Aparece en las colecciones:Tesis Física (FISICA)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CD 9700.pdf12,05 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.