dc.identifier.citationRios Sigcho, J. F. (2019). Coordinación de aislamiento para la línea a 500 kV, doble circuito, de la interconexión Ecuador-Perú por sobrevoltaje de maniobra. 92 hojas. Quito : EPN.es_ES
dc.identifier.otherT-IE/4902/CD 9798-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/20329-
dc.descriptionSe determinó el sobrevoltaje de disrupción crítico en base a la distancia crítica de acuerdo al método convencional para la coordinación de aislamiento por sobrevoltaje de maniobra, considerando la altitud del lugar por donde se estima va a tener lugar la línea de transmisión para la interconexión Ecuador- Perú. Con el valor del sobrevoltaje de disrupción crítico y con el valor del sobrevoltaje de maniobra máximo generado por el recierre con carga atrapada de la línea de transmisión mediante el software ATP, se calculó el riesgo de falla por sobrevoltaje de maniobra, mediante el método de diseño probabilístico y con la ayuda del software Python se determinó una solución a la integral que se plantea en el método probabilístico, con la implementación de un método numérico. Finalmente, se determinó el número de aisladores de acuerdo a la distancia crítica calculada sin sobrepasar el uno por ciento del riesgo de falla por sobrevoltaje de maniobra considerando la influencia de viento en los aisladores de acuerdo a la disposición en la torre, se presentan alternativas de diseño para la coordinación del aislamiento de la línea de transmisión doble circuito a 500 kV Ecuador-Perú por sobrevoltaje de maniobraes_ES
dc.description.abstractThe critical flashover was determined based on the strike distance according to the conventional method for the insulation coordination for switching overvoltage, considering the altitude of the place where the transmission line for the Ecuadorian interconnection is estimated to take place. Peru. With the value of critical flashover and the value of switching overvoltage peak generated by reclosing with trapped charge of the transmission line using the ATP software, the probability of flashover for switching overvoltage was calculated by the design probabilistic method and with the help of Python software, a solution was determined to the integral that develop in the probabilistic method, with the implementation of a numerical method. Finally, the number of insulators according to the strike distance calculated not to exceed one percent of the probability of flashover for switching overvoltage considering the influence of wind on insulators according to the arrangement in the tower was determined presented alternatives design for the insulation coordination of the transmission line double circuit to 500 kV Ecuador-Peru for switching overvoltage.es_ES
dc.description.sponsorshipVillacís Salazar, Hugo Marcelo, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2019.es_ES
dc.rightsopenAccesses_ES
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectVOLTAJEes_ES
dc.subjectTRANSMISIÓNes_ES
dc.subjectCIRCUITOes_ES
dc.titleCoordinación de aislamiento para la línea a 500 kV, doble circuito, de la interconexión Ecuador-Perú por sobrevoltaje de maniobraes_ES