Por favor, use este identificador para citar o enlazar este ítem:
http://bibdigital.epn.edu.ec/handle/15000/20544
Registro completo de metadatos
Campo DC | Valor | Lengua/Idioma |
---|---|---|
dc.contributor.author | Villacís Suárez, Santiago Javier | - |
dc.date.accessioned | 2019-11-19T15:07:02Z | - |
dc.date.available | 2019-11-19T15:07:02Z | - |
dc.date.issued | 2019-11-07 | - |
dc.identifier.citation | Villacís Suárez, S. J. (2019). Estimación de ruido audible para la línea de transmisión Santiago - Pasaje 500 kV doble circuito. 124 hojas. Quito : EPN. | es_ES |
dc.identifier.other | T-IE/4965/CD 10037 | - |
dc.identifier.uri | http://bibdigital.epn.edu.ec/handle/15000/20544 | - |
dc.description | El presente proyecto presenta una estimación de ruido audible mediante formulaciones encontradas en la bibliografía, mismas que fueron adecuadas para las condiciones geográficas y climáticas del Ecuador continental, estas fórmulas se aplicaron en dos casos: línea de transmisión San Rafael – El Inga 500 kV simple circuito y el proyecto de línea de transmisión Santiago – Pasaje 500 kV doble circuito. En la línea de transmisión San Rafael – El Inga, al estar ya diseñada e implementada, se procedió a estimar el ruido audible generado en condiciones lluviosas (conductor húmedo) y se demostró que los niveles de dicho fenómeno no superaron el estándar establecido por la BPA (Boneville Power Administration). Para el proyecto de línea de transmisión Santiago – Pasaje, se determinaron los parámetros eléctricos idóneos tendientes a mitigar el ruido audible generado, en base a estos parámetros se procede con la estimación de dicho fenómeno obteniendo en la línea de transmisión Santiago – Pasaje niveles aceptables de ruido audible según la BPA | es_ES |
dc.description.abstract | The present project presents an estimate of audible noise by means of formulations found in the bibliography that were suitable for the geographical and climatic conditions of continental Ecuador, which were applied for two cases: transmission line San Rafael - El Inga 500 kV simple circuit and the project of transmission line Santiago - Pasaje 500 kV double circuit. For the transmission line San Rafael - El Inga it is a transmission line already designed and implemented, the present project estimates the audible noise generated in rain conditions (wet conductor) and it is shown that the levels of this phenomenon do not exceed the standard established by BPA (Boneville Power Administration). For the Santiago - Pasaje transmission line project, the determination of the ideal electrical parameters is presented with the objective of mitigating the audible noise generated. This phenomenon is estimated, leaving the transmission line project under acceptable levels of noise according to the BPA | es_ES |
dc.description.sponsorship | Plazarte Achig, Juan Carlos, director | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Quito, 2019. | es_ES |
dc.rights | openAccess | es_ES |
dc.rights.uri | https://creativecommons.org/licenses/by-nc-nd/4.0/ | - |
dc.subject | ENERGÍA ELÉCTRICA | es_ES |
dc.subject | RADIOTRANSMISIÓN | es_ES |
dc.subject | RADIO INTERFERENCIA | es_ES |
dc.title | Estimación de ruido audible para la línea de transmisión Santiago - Pasaje 500 kV doble circuito | es_ES |
dc.type | bachelorThesis | es_ES |
Aparece en las colecciones: | Tesis Ingeniería Eléctrica (IE) |
Ficheros en este ítem:
Fichero | Descripción | Tamaño | Formato | |
---|---|---|---|---|
CD 10037.pdf | 11,35 MB | Adobe PDF | Visualizar/Abrir |
Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.