Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/20820
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorBrusil Guamán, Mayté Carolina-
dc.date.accessioned2020-04-20T20:59:40Z-
dc.date.available2020-04-20T20:59:40Z-
dc.date.issued2020-04-15-
dc.identifier.citationBrusil Guamán, M. C. (2020). Análisis de perturbaciones armónicas producidas por luminarias de tecnología LED en una red de alumbrado público. 122 hojas. Quito : EPN.es_ES
dc.identifier.otherT-IE/5034/CD 10342-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/20820-
dc.descriptionLa tecnología LED ha ido rápidamente reemplazando a otras fuentes de iluminación como lámparas de vapor de sodio y vapor de mercurio. Las lámparas y luminarias LED tienen amplias ventajas y en la actualidad se usan en hogares, industrias, monumentos y alumbrado público. Por otro lado, estas pueden tener efectos negativos en la calidad de la energía debido a la distorsión de corriente que inyectan a la red. En este sentido el siguiente proyecto evalúa el impacto que la instalación de luminarias LED tendría en las redes de alumbrado público, mediante medición, modelación y simulación de un caso de estudio en el que se reemplazan luminarias de tecnología de vapor de sodio de alta presión por luminarias de tecnología LED. El proyecto contiene un diseño de iluminación vial y mediciones de contenido armónico que permiten modelar las fuentes armónicas en la red de distribución. Se describe una metodología de análisis de perturbaciones armónicas y por medio de los resultados obtenidos de simulación se compara el impacto que tienen las perturbaciones armónicas producidas por cada tipo de tecnología en la red de distribución. Finalmente se realiza un análisis financiero para determinar la viabilidad del proyecto de sustitución de las luminarias.es_ES
dc.description.abstractLight-emitting-diode (LED) lighting is replacing other lighting sources such as mercury and sodium high intensity discharge (HID) lamps. LED technology has multiple advantages over its predecessors and it is currently used in homes, industries, monuments and even for street lighting. On the other hand, LED luminaries and LED lamps could have negative effects on distribution system quality due to the current distortion they inject into the grid. In this sense, the following project evaluates the impact that LED luminaires could have in public lighting networks by measuring, modeling and simulating a study case in which high pressure sodium luminaires are replaced by LED luminaires. The project contains a road lighting design and harmonic measurements. Measurement results are used to model harmonic sources in the distribution system. Simulation results of total harmonic distortion on the distribution system allow to compare both technologies. According to the results obtained, the impact of the LED luminaires on the system is analyzed. Finally, a financial analysis is carried out, considering two alternatives, the first, replacing HID luminaires with LED luminaires, and the second, maintaining HID technology in the public lighting network.es_ES
dc.description.sponsorshipArcos Martínez, Hugo Neptalí, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2020.es_ES
dc.rightsopenAccesses_ES
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectARMÓNICOSes_ES
dc.subjectLUMINARIASes_ES
dc.subjectPRESIÓNes_ES
dc.titleAnálisis de perturbaciones armónicas producidas por luminarias de tecnología LED en una red de alumbrado públicoes_ES
dc.typebachelorThesises_ES
Aparece en las colecciones:Tesis Ingeniería Eléctrica (IE)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CD 10342.pdf2,36 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.