dc.identifier.citationBrusil Angamarca, J. A. & Peñafiel Mocha, H. D. (2020). Estudio experimental de mampostería postensada resistente a cargas laterales y verticales, constituida por bloques de hormigón tipo lego. 154 hojas. Quito : EPN.es_ES
dc.identifier.otherT-IC/1018/CD 10597-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/21086-
dc.descriptionLa mampostería convencional no reforzada presenta un comportamiento deficiente al soportar cargas y momentos dentro y fuera del plano, lo que lleva a un tipo de falla frágil de baja ductilidad. En este estudio se pretende introducir un refuerzo postensado en la mampostería que minimice los daños ocasionados. Estos daños se presentan debido a la ocurrencia de un sismo y suelen manifestarse generando grietas. En Ecuador, al no contar con normas técnicas para el diseño de mampostería postensada que guíen en los procedimientos constructivos, características y propiedades de los materiales a emplearse, es necesario estudiar las características de muretes de albañilería con refuerzo postensado en una y dos direcciones. Fueron realizados ensayos de compresión axial y compresión diagonal sobre un total de 27 muretes. Con base en los resultados de los ensayos, se determinaron experimentalmente, la resistencia a compresión y corte, los módulos de elasticidad y de cortante. Finalmente, se determinó que al reforzar la mampostería verticalmente con elementos tensados, la resistencia a corte se incrementa al doble y el módulo cortante se incrementa un 57% frente a los valores determinados en la mampostería sin refuerzo, siendo esta la configuración de refuerzo óptima por sus características y facilidad de construcción.es_ES
dc.description.abstractConventional unreinforced masonry has poor performance to the support loads and moments in and out of the plane, leading to a type of low ductility brittle failure. This study aims to introduce a post-tensioned reinforcement in the masonry to minimize damage. These damages occur due to the occurrence of an earthquake and usually manifest as cracks. In Ecuador, as there are no technical standards for the design of post-tensioned masonry to guide the construction procedures, characteristics and properties of the materials to be used, it is necessary to study the characteristics of masonry walls with post-tensioned reinforcement in one and two directions. Axial and diagonal compressive tests were carried out on a total of 27 low walls. Based on the results of the tests, the compressive strength and shear, moduli of elasticity and shear were determined experimentally. Finally, it was determined that when reinforcing the masonry vertically with tensioned elements, the shear resistance is doubled and the shear modulus increases by 57% compared to the values determined in the unreinforced masonry, this being the optimal reinforcement configuration for its characteristics and ease of construction.es_ES
dc.description.sponsorshipVintimilla Jaramillo, Jorge Ricardo, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2020.es_ES
dc.rightsopenAccesses_ES
dc.subjectRESISTENCIA DE MATERIALESes_ES
dc.subjectHORMIGÓNes_ES
dc.subjectMAMPOSTERÍA POSTENSADAes_ES
dc.titleEstudio experimental de mampostería postensada resistente a cargas laterales y verticales, constituida por bloques de hormigón tipo legoes_ES