dc.date.issued | 2018-07-27 | - |
dc.identifier.citation | Manzano Suarez, M. E. & Zúñiga Morales, P. S. (2020). Análisis del comportamiento ante cargas laterales de la unión soldada entre columna compuesta y viga de alma llena, reforzada con anillo rigidizante, en nudos interiores de pórticos resistentes a momento. 182 hojas. Quito : EPN. | es_ES |
dc.identifier.other | T-MVE/0870/CD 10634 | - |
dc.identifier.uri | http://bibdigital.epn.edu.ec/handle/15000/21118 | - |
dc.description | En nuestro país existe un incremento de construcciones que utilizan el acero A-36 como material principal para sus columnas y vigas, mismas que conforman un sistema de pórticos resistentes a momento. Para analizar este tipo de sistema, se diseñó la estructura de una casa de dos pisos, considerando la norma NEC-15, cuyos elementos estructurales son columnas compuestas rellenas de hormigón, y vigas de acero de alma llena, las dos de acero estructural ASTM A-36. La investigación considera una comparación de los resultados entre un ensayo experimental y un modelo teórico diseñado en ETABS y validado en SEISMOESTRUCT. Para el ensayo experimental, se construyeron tres ejemplares del pórtico central de la casa, a escala real, los cuales se ensayaron a carga lateral. Se realizó la comparación en el punto más crítico que es el nudo central del primer piso; analizando los resultados entre los pórticos con diferentes refuerzos: unión simple soldada (pórtico 1), unión soldada con anillo rigidizante rectangular (pórtico 2) y unión soldada con anillo rigidizante trapezoidal (pórtico 3); el mejor resultado respecto a capacidad de carga del pórtico obtenido se presenta al utilizar el anillo trapezoidal, donde se ha obtenido los resultados experimentales más cercanos a los resultados teóricos. | es_ES |
dc.description.abstract | In our country there is an increase in constructions that use A-36 steel as the main material for their columns and beams, which make up a system of moment resistant frames. To analyze this type of system, the structure of a two-floor house was designed, considering the NEC-15 standard, the structural elements are composite by columns filled with concrete, and full-web steel beams, both made of ASTM A-36 structural steel. This research considers a comparison of the results between an experimental test and a theoretical model designed in ETABS and validated in SEISMOESTRUCT. For the experimental test, three specimens of the central portico of the house were built, on a real scale, which were tested under lateral load. The comparison was made at the most critical point, which is the central node of the first high floor; analyzing the results between the frames with different reinforcements: simple welded joint (frame 1), welded joint with rectangular stiffening ring (frame 2) and welded joint with trapezoidal stiffening ring (frame 3); the best result regarding the load capacity of the portico obtained is presented when using the trapezoidal ring, where the experimental results closest to the theoretical results have been obtained. | es_ES |
dc.description.sponsorship | Vintimilla Jaramillo, Jorge Ricardo, director | es_ES |
dc.language.iso | spa | es_ES |
dc.publisher | Quito, 2020. | es_ES |
dc.rights | openAccess | es_ES |
dc.subject | ESTRUCTURAS | es_ES |
dc.subject | ACERO | es_ES |
dc.subject | ANÁLISIS ESTRUCTURAL | es_ES |
dc.title | Análisis del comportamiento ante cargas laterales de la unión soldada entre columna compuesta y viga de alma llena, reforzada con anillo rigidizante, en nudos interiores de pórticos resistentes a momento | es_ES |