dc.contributor.authorCevallos Granda, Kelvin Cristopher-
dc.date.accessioned2021-05-31T17:34:13Z-
dc.date.available2021-05-31T17:34:13Z-
dc.date.issued2021-05-26-
dc.identifier.citationCevallos Granda, K.C. (2021). Implementación de la acometida para el tablero general del Laboratorio de Tecnología Industrial-ESFOT. 40 hojas: Quito : EPN.es_ES
dc.identifier.otherT-TEM/0258/CD 11133-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/21653-
dc.descriptionEn base a la necesidad de un nuevo tablero general, se implementó una nueva acometida eléctrica correctamente dimensionada para abastecer de manera adecuada a los laboratorios de la ESFOT. Esto permitirá usar el nuevo tablero general como tablero de distribución para los laboratorios de la ESFOT abasteciéndolos de manera simultánea. Además, la acometida cuenta con su protección eléctrica para su cuidado, garantizando su fiabilidad de operación ante cualquier evento que se desarrolle en los laboratorios. En la primera sección se da a conocer el problema a solventar y los respectivos objetivos. En la segunda sección se detalla los procesos metodológicos que se emplearon para el desarrollo y solución del problema planteado. En la tercera sección se describe cómo se definió la trayectoria adecuada para el conductor, a continuación, se expone los cálculos del dimensionamiento del conductor y su protección correspondiente tomando en cuenta la carga actual instalada y futuras ampliaciones. Además, se presenta el plano eléctrico realizado en el programa de AUTOCAD y se detalla el procedimiento que se realizó para la instalación de cada uno de los componentes, luego se efectuó las pruebas de funcionamiento de la acometida.es_ES
dc.description.abstractBased on the need for a new general panel, a new electrical connection was implemented, correctly dimensioned to adequately supply the ESFOT laboratories. This will allow the new general board to be used as a distribution board for the ESFOT laboratories, supplying them simultaneously. In addition, the connection has its electrical protection for its care and protection, guaranteeing its operational reliability in the event of any event that takes place in the laboratories. In the first section, the problem to be solved and the respective objectives are disclosed. The second section details the methodological processes that were used for the development and solution of the proposed problem. The third section describes how the proper path for the conductor was defined, then the calculations of the conductor sizing and its corresponding protection are exposed, considering the current installed load and future extensions. In addition, the electrical plan made in the AUTOCAD program is presented and the procedure that was carried out for the installation of each of the components is detailed, then the operation tests of the connection were carried out.es_ES
dc.description.sponsorshipLoja Romero, Abraham Ismael, directores_ES
dc.publisherQuito, 2021es_ES
dc.rightsopenAccesses_ES
dc.subjectELECTROMECÁNICAes_ES
dc.subjectPROTECCIÓN ELÉCTRICAes_ES
dc.titleImplementación de la acometida para el tablero general del Laboratorio de Tecnología Industrial-ESFOT.es_ES
dc.typebachelorThesises_ES