Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/7838
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorEnríquez Quelal, José Carlos-
dc.date.accessioned2014-07-17T21:11:40Z-
dc.date.available2014-07-17T21:11:40Z-
dc.date.issued2014-07-
dc.identifier.otherT-IE/3958/CD 5657-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/7838-
dc.description229 hojas : ilustraciones, 29 x 21 cm + CD 5657es_ES
dc.description.abstractLos sistemas de potencia están incrementando su complejidad, por esta razón se necesita de ingenieros eléctricos y operadores con conocimientos sólidos del sistema. Los simuladores digitales se han abierto paso debido al auge de los computadores sin embargo son limitados porque no brindan una comprensión física de los fenómenos que ocurren dentro del sistema y no son capaces de predecir fenómenos anormales, por estas razones se necesita un modelo físico. Con esto en mente este trabajo pretende dar inicio a un laboratorio con modelos a escala interconectados como un sistema de potencia. Para conseguir este fin se diseña módulos de líneas de transmisión trifásicas a doble circuito de 50, 30 y 10 km de longitud. La configuración del modelo del Sistema Nacional Interconectado corresponde a la del anillo de 230 kV reducido a 5 barras principales: Santa Rosa, Totoras, Paute, Pascuales y Quevedo. Cada módulo está formado de 42 capacitores de potencia para representar el acoplamiento electrostático, 6 bobinas de núcleo de aire para el acoplamiento mutuo y 7 bobinas de núcleo de hierro para la inductancia propia de la línea de transmisión.-- ABSTRACT: Power systems are increasingly complex, for this reason it demands that electrical engineers and operators have a solid knowledge of the system. Digital simulators have made their way due to the rise of computers however they are limited since they do not provide a physical understanding of the phenomena occurring within the system and are not able to predict abnormal events, for these reasons, a physical model is needed. With this in mind this work aims to start a laboratory with scale models interconnected as a power system. To achieve this purpose double circuit three phase line module of 50, 30 and 10 km in length were designed for a scale model of the national grid. Model configuration corresponds to the 230 kV ring, reduced in to 5 main bars: Santa Rosa, Totoras, Paute, Pascuales and Quevedo. Each module consist of 42 power capacitors to represent the electrostatic coupling, six air core coils for the mutual coupling and 7 iron core coils for the self-inductance of the transmission linees_ES
dc.description.sponsorshipJátiva Ibarra, Jesús Amado, directores_ES
dc.language.isospaes_ES
dc.publisherQuito : EPN, 2014.es_ES
dc.rightsopenAccess-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectSistemas eléctricos de potenciaes_ES
dc.subjectLíneas de transmisiónes_ES
dc.subjectSistema nacional interconectadoes_ES
dc.subjectEcuadores_ES
dc.titleConceptualización de la red de transmisión de 230 kV para un modelo a escala del sistema nacional interconectado reducidoes_ES
dc.typebachelorThesises_ES
Aparece en las colecciones:Tesis Ingeniería Eléctrica (IE)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CD-5657.pdf19,32 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.