Please use this identifier to cite or link to this item: http://bibdigital.epn.edu.ec/handle/15000/9116
Title: Monitoreo en Tiempo Real de Oscilaciones de Potencia en el Corredor Oriental Molino – Totoras - Santa Rosa - Pomasqui Utilizando Mediciones Sincrofasoriales de las Subestaciones Pomasqui y Molino a Nivel de 230 kV.
Authors: Tapia Suárez, Estefanía Alexandra
Keywords: Potencia
Algoritmos
Sistemas eléctricos de potencia
Issue Date: 12-Dec-2014
Publisher: Quito : EPN, 2015.
Abstract: Resumen .- En este trabajo se investigan y aplican los algoritmos Power Swing Detection, PSD y Predictive Out of Step Tripping, OOST, los cuales basan su funcionamiento en mediciones sincrofasoriales para la detección de condiciones oscilatorias y pérdida de sincronismo. Los algoritmos son dirigidos al problema de estabilidad angular que presenta el Sistema Nacional Interconectado (SNI) con el Sistema Eléctrico Colombiano ante contingencias N-2 en ciertas zonas de la Red Troncal de 230 kV, lo cual puede desencadenar condiciones oscilatorias inestables o bien la pérdida de sincronismo, si estas condiciones no son detectadas a tiempo y no se realizan acciones de control. Se desarrolla una herramienta computacional en Visual Basic, basada en mediciones sincrofasores. Se determinan previamente los parámetros característicos de ajuste de los algoritmos, los mismos que dependen de cada sistema de potencia. Esta herramienta permite observar y monitorear en tiempo real el comportamiento dinámico de los generadores cercanos a las barras de donde se obtienen las mediciones sincrofasoriales, además permite detectar condiciones oscilatorias estables e inestables, representando una herramienta adicional para la toma de decisiones. Abstract .- The algorithms denominated Power Swing Detection – PSD and Predictive Out-Of-Step Tripping – OOST are studied and applied in this work, whose operation is based on synchrophasor measurements for the detection of oscillatory conditions and loss of synchronism. These algorithms are aimed at dealing with the problem of angular stability presented by the National Interconnected System (SNI) with the Colombian System when contingencies N-2 in certain areas of 230 kV grid occur, which can trigger unstable oscillatory conditions or loss of synchronism, if these conditions are not detected on time and any control actions are executed. A computational tool on Visual Basic, based on synchrophasor measurements, is developed for PSD and OOST algorithms. Adjustment characteristic parameters for the algorithms are determined, which depends on each system. This tool allows to monitor the dynamic behavior in real time of the generators near busses where synchrophasors measurements are obtained, in addition they allow to detect stable and unstable oscillatory conditions, representing an additional tool for decision making.
Description: 155 hojas : ilustraciones, 29 x 21 cm + CD-ROM 6070
URI: http://bibdigital.epn.edu.ec/handle/15000/9116
Type: bachelorThesis
Appears in Collections:Tesis Ingeniería Eléctrica (IE)

Files in This Item:
File Description SizeFormat 
CD-6070.pdfTesis completa2,83 MBAdobe PDFView/Open


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.