Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/10529
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorHaro Naranjo, Diana Patricia-
dc.date.accessioned2015-05-11T18:07:36Z-
dc.date.available2015-05-11T18:07:36Z-
dc.date.issued2015-05-06-
dc.identifier.otherT-IE/4082/CD 6229-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/10529-
dc.description140 hojas : ilustraciones, 29 x 21 cm + CD-ROM 6229es_ES
dc.description.abstractResumen .- La mayoría de los transformadores de distribución de la EEQ se encuentran con factores de utilización bajos, de alrededor del 20-30%, que hacen que su capacidad instalada no sea bien aprovechada y genere pérdidas adicionales de energía. En varios casos existe una aglomeración de transformadores de distribución en las calles de la ciudad, un claro ejemplo es la calle de los Cipreses donde existen 17 transformadores en una longitud de red de 729 m, con una carga predominantemente residencial, por lo que se adopta como el caso de estudio. Para mejorar la situación existente, se analizan los factores de utilización de los transformadores de distribución en la situación actual y la posibilidad de agrupar cargas para reducir el número de transformadores, cabe resaltar que dentro del estudio de la situación con carga agrupada se incluye la incorporación de las cocinas de inducción, debido a que se trata de una política gubernamental en desarrollo por lo que la red de distribución se debe preparar para esta nueva carga. Los resultados del caso de estudio reflejan que se logra disminuir el número de transformadores de distribución de 17 a 8; liberando 9 para reutilizarlos en cualquier otro lugar que requiera la EEQ, además se logran disminuir las pérdidas de energía anuales de 40839.4 a 13157.2 kWh, en los transformadores. La red secundaria, con las secciones añadidas y la nueva carga, tiene un incremento de pérdidas de 9734.1 kWh. La reducción neta de pérdidas es de 17948.1 kWh, que representa un ahorro anual de USD 1435.7 para la EEQ. La inversión ahorrada en transformadores representa USD 22600, considerando una depreciación del 50% de su precio original. Todo esto permite plantear una metodología adecuada para mejorar los factores de utilización de los transformadores y cumplir con los objetivos propuestos del proyecto. Abstract .- The majority of the EEQ distribution transformers are underused, with low utilization factors of around 20-30%, making non-profitable the installed capacity in distribution transformers and generating additional energy losses. In several cases there is an agglomeration of distribution transformers in the city streets, a clear example is the Cypress street where there are 17 transformers on a length of 729 m, with a predominantly residential load, that is why it is adopted as the study case. In order to improve the observed situation, the distribution transformers utilization factors were analyzed along with the possibility of grouping loads, to reduce the number of transformers. It must be highlighted, the study of the situation with grouped loads considers the incorporation of induction ranges, since there is a governmental policy already being applied and the distribution network must be prepared for this new load. The results of the study case reflect that a reduction is achieved on the distribution transformers number from 17 to 8; freeing 9 for reuse anywhere else that requires the EEQ. Also achieved a reduction of annual energy losses, in transformers, from 40839.4 to 13157.2 kWh. The secondary circuits, with the new sections and additional load, increased the energy losses in 9734.1 kWh. Then, the net annual reduction of losses is 17948.1 kWh, representing an annual savings of USD 1435.7 to EEQ. The investment saved in transformers means USD 22600, taking into account a 50% depreciation from their original price. This allows the development of an appropriate methodology to improve utilization factors of the transformers and meet the objectives of the project.es_ES
dc.description.sponsorshipPoveda Almeida, Mentor Estuardo, directores_ES
dc.language.isospaes_ES
dc.publisherQuito : EPN, 2015.es_ES
dc.rightsopenAccess-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectEnergía electricaes_ES
dc.subjectRedes eléctricases_ES
dc.titleMejora del factor de utilización de los transformadores de la EEQes_ES
dc.typebachelorThesises_ES
Aparece en las colecciones:Tesis Ingeniería Eléctrica (IE)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CD-6229.pdf3,3 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.