Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/10583
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorChicaiza Díaz, Diego Moisés-
dc.contributor.authorArcos López, Esteban Ricardoes_ES
dc.date.accessioned2015-05-21T16:32:13Z-
dc.date.available2015-05-21T16:32:13Z-
dc.date.issued2015-05-20-
dc.identifier.otherT-TEM/0161/CD 6261-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/10583-
dc.description111 hojas : ilustraciones, 29 x 21 cm + CD-ROM 6261es_ES
dc.description.abstractResumen .- Los equipos que operan con corriente alterna, cuyo funcionamiento se basa en el electromagnetismo, generando sus propios campos electromagnéticos se manifiestan como potencia activa, reactiva y aparente. El factor de potencia es la relación entre las potencias activa y aparente y está determinado por el tipo de cargas conectadas a la instalación. Al introducir cargas inductivas y reactivas, el factor de potencia varia retrasando o adelantando la intensidad de corriente respecto a la diferencia de potencial en el sistema eléctrico. Ese desfase es el que mide el factor de potencia. Para corregir el factor de potencia se puede utilizar varios medios según sea el caso, no obstante el empleo de bancos automáticos de condensadores es la opción más adecuada. Este tipo de corrección permite controlar por pasos la conexión y desconexión de los condensadores según sea el requerimiento para lograr el factor de potencia deseado, para este proyecto de tesis se ha utilizado un módulo automático el cual a su vez está controlado por un microprocesador. La compensación de la energía reactiva se realiza mediante la instalación en la red eléctrica de baterías de condensadores eléctricos, los cuales generan cargas capacitivas que contrarrestan las pérdidas reactivas de la instalación. Abstract .- The teams that operate with alternating current, whose operation is based on electromagnetism, generate their own electromagnetic fields manifest themselves as active, reactive and apparent power. The Power factor is the relation between the active and apparent powers and is determined by the type of loads connected to the installation. When entering inductive and reactive loads, power factor varies by delaying or advancing the intensity of current with respect to the potential difference in the electrical system. This phase lag is the one that measures the power factor. To correct the power factor it can be used several ways as it is the case; however the use of automatic capacitor banks is the most suitable option. This type of correction by steps allows controlling the connection and disconnection of the capacitors according to the requirement to achieve the desired power factor, for this thesis project there has been used an automatic module which in turn is controlled by a microprocessor. Reactive energy compensation is done by the installation in the electrical network in batteries of electric capacitors, which generate capacitive loads counteracting reactive losses of the installation.es_ES
dc.description.sponsorshipCastro Macancela, Germán Enrique, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2015.es_ES
dc.rightsopenAccess-
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/-
dc.subjectPotenciaes_ES
dc.subjectEnergía eléctricaes_ES
dc.subjectAutomatización y control industriales_ES
dc.titleDiseño y construcción de un tablero de control automático para corrección del factor de potencia, empleando un Módulo DCRA.es_ES
dc.typebachelorThesises_ES
Aparece en las colecciones:Tesis Electromecánica (EM)