dc.identifier.citationTorres Jaramillo, P. X., & Matango Angamarca, A. S. (2017). Evaluación y comparación del reforzamiento de la PUCE sede Bahía, mediante la utilización de disipadores de energía tipo Shear-Link respecto a un reforzamiento con muros de corte. 263 hojas. Quito : EPN.es_ES
dc.identifier.otherT-IC/0828/CD 8372-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/18974-
dc.descriptionSe presenta una propuesta teórica para el reforzamiento de una edificación afectada por el sismo del 16/04/2016, mediante el uso de disipadores de energía tipo Shear Link Bozzo. Esta propuesta se compara con un reforzamiento en el que se usó muros de corte. Se ha realizado un análisis estático no lineal por el método del espectro de capacidad, tanto en la estructura original como en la estructura reforzada con muros y en el reforzamiento con disipadores de energía, con el fin de conocer sus curvas de capacidad y sus puntos de desempeño. De la norma ecuatoriana de la construcción NEC-15 se ha determinado el espectro de diseño, el cual, junto con la curva de capacidad, han permitido determinar los puntos de desempeño de las estructuras reforzadas y original. Estos puntos representan el máximo desplazamiento al que la estructura estará sometida si se presentase el sismo de diseño, razón por la cual se ha realizado una comparación de la capacidad estructural y derivas en este punto. Para realizar un análisis Pushover se ha requerido una distribución de fuerzas laterales, mismas que han sido calculadas a partir los modos de vibración de la estructura y mediante métodos simplificados expuestos por la NEC-15.es_ES
dc.description.abstractIt is presented a theoretical proposal for a structural retrofitting by Shear Link Bozzo energy dissipation devices applied on an edification which was affected by the earthquake occurred in 16/04/2016 located in Ecuador. This proposal has been compared with a reinforcement alternative in which had being used shear walls. A nonlinear static analysis Pushover has been conducted in the original structure as well as the reinforced ones with walls and energy dissipation devices, in order to obtain its capacity curves and performance points. The Ecuadorian Building Code NEC-15, and the characteristics of the edification and its location have been used to determine the design response spectrum that, together with the capacity curve of the structures, have allowed to obtain the performance points of the reinforced structures and the original one. These points represent the maximum displacement at which each structure will be subjected if the design earthquake happened; for this reason, a comparison of the structural capacity and the inelastic drifts at that point has been made. To perform a pushover analysis require a distribution of lateral forces, these forces have been calculated through the vibration modes of the structure and following the NEC-15.es_ES
dc.description.sponsorshipMora Martínez, Edgar David, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2017es_ES
dc.rightsopenAccesses_ES
dc.subjectESTRUCTURAS (CONSTRUCCION)es_ES
dc.subjectINGENIERIA SISMICAes_ES
dc.titleEvaluación y comparación del reforzamiento de la PUCE sede Bahía, mediante la utilización de disipadores de energía tipo Shear-Link respecto a un reforzamiento con muros de corte.es_ES
dc.typebachelorThesises_ES