Por favor, use este identificador para citar o enlazar este ítem: http://bibdigital.epn.edu.ec/handle/15000/20077
Registro completo de metadatos
Campo DCValorLengua/Idioma
dc.contributor.authorMejía Estévez, Inés Gabriela-
dc.contributor.authorUrcuango Conumba, Cynthia Yanina-
dc.date.accessioned2019-02-21T16:43:11Z-
dc.date.available2019-02-21T16:43:11Z-
dc.date.issued2019-01-14-
dc.identifier.citationMejía Estévez, I.G. / Urcuango Conumba, C. Y. (2019). Propuesta de tratamiento de aguas grises provenientes de duchas y lavabos para su reutilización en inodoros. 136 hojas. Quito : EPN.es_ES
dc.identifier.otherT-IC/0932/CD 9517-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/20077-
dc.descriptionSe presenta una propuesta de tratamiento de aguas grises generadas en duchas y lavamanos mediante un proceso de oxidación con peróxido de hidrógeno o hipoclorito de calcio para su recirculación hacia los inodoros, aplicado a un caso de estudio. La campaña de muestreo ayudó a establecer el caudal de agua gris generado en duchas y lavamanos de 55,8 l/hab.día. El análisis de consumo de agua según el tipo de inodoros estableció que el caudal de agua gris necesario a tratar es de 27,73 l/hab.día, La caracterización del agua gris mediante parámetros físicos, químicos y biológicos, permitió determinar que la contaminación del agua gris es media. El agua gris fue tratada con diferentes dosis de peróxido de hidrógeno e hipoclorito de calcio mediante el equipo de prueba de jarras hasta encontrar las óptimas de 0,5ml/l y 3,5 g/l respectivamente. Se determinó que el hipoclorito de calcio en comparación con el peróxido de hidrogeno presenta una mayor eficiencia de remoción de nutrientes, materia orgánica y patógenos presentes en el agua gris. El análisis de costos aplicado al caso de estudio estableció que la implementación del sistema de tratamiento usando hipoclorito de calcio o peróxido de hidrógeno no varía significativamente.es_ES
dc.description.abstractA proposal of gray water treatment generated in showers and sinks is presented through a process of oxidation with hydrogen peroxide and calcium hypochlorite for its recirculation to toilets, applied to a case study. The sampling campaign helped establish the flow of gray water generated in showers and washbasins of 55.8 l / day. The analysis of water consumption according to the type of toilets established that the flow of gray water needed to treat is 27.73 l / hab.day, The characterization of the gray water by means of physical, chemical and biological parameters, allowed to determine that the gray water contamination is medium. The gray water was treated with different doses of hydrogen peroxide and calcium hypochlorite using the jar test equipment until the optimal ones were 0.5ml / l and 3.5g / l respectively. It was determined that calcium hypochlorite compared to hydrogen peroxide has a greater efficiency of removal of nutrients, organic matter and pathogens present in gray water. The cost analysis applied to the case study established that the implementation of the treatment system using calcium hypochlorite or hydrogen peroxide does not vary significantly in values.es_ES
dc.description.sponsorshipMuñoz Rodríguez, Marcelo Isaías, directores_ES
dc.language.isospaes_ES
dc.publisherQuito, 2019.es_ES
dc.rightsopenAccesses_ES
dc.subjectHIPOCLORITO DE CALCIOes_ES
dc.subjectPERÓXIDO DE HIDRÓGENOes_ES
dc.titlePropuesta de tratamiento de aguas grises provenientes de duchas y lavabos para su reutilización en inodoroses_ES
dc.typebachelorThesises_ES
Aparece en las colecciones:Tesis Ingenieria Civil y Ambiental (ICA)

Ficheros en este ítem:
Fichero Descripción TamañoFormato 
CD-9517.pdf3,27 MBAdobe PDFVisualizar/Abrir


Los ítems de DSpace están protegidos por copyright, con todos los derechos reservados, a menos que se indique lo contrario.