dc.identifier.citationCalvache Proaño, F.D. & Toapanta Chanatasig, E.J.(2022).Diseño de un sistema centralizado de calefacción para el Parque Industrial “El Obraje” ubicado en la ciudad de Machachi. 94 páginas. Quito : EPN.es_ES
dc.identifier.otherT-IM/2363/CD 12908-
dc.identifier.urihttp://bibdigital.epn.edu.ec/handle/15000/23508-
dc.descriptionEl trabajo se enfocó en el diseño y simulación de un Sistema Centralizado de Calor (DHS) para el Parque Industrial “El Obraje” ubicado en la ciudad de Machachi. Se diseñaron dos sistemas basados en bomba de calor: el primero con una fuente geotérmica (GSHP) y el segundo con fuente aerotérmica (ASHP). Tanto las cargas térmicas, el diseño y la simulación se realizó en el software TRNSYS, que permite simular sistemas energéticos en estado transitorio. Con los resultados obtenidos se comparó energética, exergética y económicamente entre los dos sistemas para determinar cuál representa una mejor opción para el acondicionamiento de los espacios estudiados. En términos energéticos, ambos sistemas cubren la demanda de las edificaciones. Sin embargo, el sistema ASHP tiene un mayor consumo eléctrico que el GSHP lo que representa un menor coeficiente de rendimiento estacional (SPF). Desde la parte exergética se realizó el análisis del coeficiente de rendimiento exergético (COP) en donde la diferencia entre los sistemas GSHP Y ASHP es de un 4%. Por otra parte, en el análisis económico se tomaron en cuenta los costos de instalación y operación, en donde el sistema GSHP tiene una inversión 4 veces mayor a la del sistema ASHP. Sin embargo, en los costos de operación el sistema ASHP es el doble frente al GSHP, lo que hace que, a lo largo de la vida útil del sistema, el sistema GSHP sea más barato que el ASHP. Considerando estos puntos en conjunto, se determinó que el sistema GSHP presenta una mayor ventaja para este proyecto.es_ES
dc.description.abstractThe study aimed at the design and simulation of a District heating system (DHS) for the Industrial Park "El Obraje" in the city of Machachi. Two systems based on heat pump were designed: the first with a ground source (GSHP) and the second with an air source (ASHP). Thermal loads, design and simulation were developed and carried out in the TRNSYS software, which allows simulating energetic systems in a transient state. From the results obtained, an energetic, exergetic and economic comparison was made between both systems to determine which one represents a better option for the conditioning of the spaces studied. In terms of energy, both systems satisfied the demand of the buildings. However, the ASHP system has a greater power consumption than the GSHP, which represents a lower seasonal performance factor (SPF). An analysis of the coefficient of exergetic performance (COP) was carried out, where the difference between the GSHP and ASHP systems was 4%. On the other hand, the economic analysis considered the installation and operation costs, where the GSHP system has an investment 4 times greater than the ASHP system. Nevertheless, in terms of operating costs, the ASHP system is twice as expensive as the GSHP system, which means that, over the useful life of the system, the GSHP system is cheaper than the ASHP system. These points taken together, the GSHP system was determined to have a greater advantage for this project.es_ES
dc.description.sponsorshipVaca Jiménez, Santiago David, director.es_ES
dc.language.isospaes_ES
dc.publisherQuito : EPN, 2022.es_ES
dc.rightsopenAccesses_ES
dc.subjectMECÁNICAes_ES
dc.subjectCALORes_ES
dc.subjectRECURSOS ENERGÉTICOSes_ES
dc.subjectRECURSOS NATURALESes_ES
dc.titleDiseño de un sistema centralizado de calefacción para el Parque Industrial “El Obraje” ubicado en la ciudad de Machachi.es_ES